内容描述: HVIC高压半桥驱动器600伏/ 【 500毫安 [HVIC High Voltage Half-Bridge Driver 600 Volts/【500mA]
分类和应用: 外围驱动器驱动程序和接口接口集成电路光电二极管高压
文件页数/大小: 4 页 / 215 K
品牌: POWEREX [ POWEREX POWER SEMICONDUCTORS ]
 浏览型号M81713FP的Datasheet PDF文件第1页浏览型号M81713FP的Datasheet PDF文件第2页浏览型号M81713FP的Datasheet PDF文件第4页  
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
M81713FP
HVIC, High Voltage Half-Bridge Driver
600 Volts/±500mA
Electrical Characteristics,
T
a
= 25°C, V
CC
= V
BS
(= V
B
– V
S
) = 15V unless otherwise specified
Characteristics
V
CC
Supply UV Filter Time
Output High Level Short Circuit Pulsed Current
Output Low Level Short Circuit Pulsed Current
Output High Level ON Resistance
Output Low Level ON Resistance
Dead Time LO Turn-Off to HO Turn-ON and
HO Turn-Off to LO Turn-On
Power On Reset Voltage
Power On Reset Filter Time
Turn-On Propagation Delay
Turn-Off Propagation Delay
High Side Turn-On Rise Time
High Side Turn-Off Fall Time
Low Side Turn-On Rise Time
Low Side Turn-Off Fall Time
V
Ponr
t
Ponr(FIL)
t
dLH
t
dHL
t
rH
t
fH
t
rL
t
fL
C
L
= 1000pF between HO – V
S
, LO – GND
C
L
= 1000pF between HO – V
S
, LO – GND
C
L
= 1000pF between LO – GND
C
L
= 1000pF between LO – GND
C
L
= 1000pF between LO – GND
C
L
= 1000pF between LO – GND
THERMAL DERATING FACTOR
CHARACTERISTICS
Symbol
tV
CCuv
I
OH
I
OL
R
OH
R
OL
t
DEAD
Test Conditions
V
O
= 0V, P
W
< 10µs
V
O
= 15V, P
W
< 10µs
I
O
= -200mA, R
OH
= (V
OH
– V
O
)/I
O
I
O
= 200mA, R
OL
= V
O
/I
O
C
L
= 1000pF between HO – V
S
, LO-GND
Min.
0.5
300
0.6
0.1
Typ.
7.5
-500
500
30
12
0.9
0.15
75
75
75
75
Max.
1.0
6
1.2
0.2
180
180
180
180
Units
µs
mA
mA
Ω
Ω
µs
Volts
ns
µs
µs
ns
ns
ns
ns
0.7
PACKAGE POWER DISSIPATION, P
d
, (WATTS)
0.6
0.5
0.4
0.3
0.2
0.1
0
0
25
50
75
100
125
150
TEMPERATURE, T
a
, (°C)
1. Input/Output Logic
HO has positive logic with reference to IN. LO has negative logic with reference to IN.
2. Logic During UV (V
CC
, V
BS
) Error
Error Signal
HO
LO
UV Error
HO outputs “L” level as long as UV error for V
CC
is detected. LO is locked at “L” as long as UV error for V
CC
is detected.
(V
CC
)*
HO responds to IN if V
CC
exceeds V
CC
UV reset level.
After V
CC
exceeds V
CC
UV reset level, the lock for LO is
removed and responds to IN signal.
UV Error
(V
BS
)
HO is locked at “L” as long as UV error for V
BS
is detected.
After V
BS
exceeds V
BS
UV reset level, the lock for HO is
removed following an “L” state of the IN signal, and then
HO responds to the input.
LO is independent of V
BS
to respond to IN.
*If UV error for VCC is detected when HO is in “H” level and the falling speed for VCC exceeds 0.03V/µm, the OFF signal for HO might not be transimitted from
low side to high side and then HO stays “H”.
3. Allowable Supply Voltage Transient
It is recommended supplying V
CC
first and V
BS
second. In the case of shutting off supply voltage, it is recommended to shut off V
BS
first and V
CC
second. At the time of starting, V
CC
and V
BS
, the power supply should be increased slowly (below 50V/µs). If it is increased
rapidly, output signal (HO or LO) may be “H”.