Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PM100CBS060
Intellimod™ Module
MAXISS Series™, Multi AXIS Servo IPM
100 Amperes/600 Volts
Thermal Characteristics
Characteristic
Junction to Case Thermal Resistance
Symbol
R
th(j-c´)Q
R
th(j-c´)F
Contact Thermal Resistance
R
th(c-f)
Condition
Each IGBT*
Each FWDi*
Case to Fin Per Module,
Thermal Grease Applied
*T
C
measured point is just under the chips.
**If you use this value, R
th(f-a)
should be mesured just under the chips.
Min.
—
—
—
Typ.
—
—
—
Max.
0.22**
0.36**
0.046
Units
°C/Watt
°C/Watt
°C/Watt
Recommended Conditions for Use
Characteristic
Supply Voltage
Control Supply Voltage***
Symbol
V
CC
V
D
V
CIN(on)
V
CIN(off)
f
PWM
t
DEAD
Condition
Applied across P-N Terminals
Applied between V
UP1-
V
UPC
,
V
VP1
-V
VPC
, V
WP1
-V
WPC
, V
N1
-V
NC
Input ON Voltage
Input OFF Voltage
PWM Input Frequency
Minimum Dead Time
Applied between U
P
-V
UPC
, V
P-
V
VPC
,
W
P-
V
WPC
, U
N
, V
N
, W
N
-V
NC
Using Application Circuit
Input Signal
≤
0.8
≥
4.0
≤
20
≥
2.5
Volts
Volts
kHz
µS
Value
≤
400
15
±
1.5
Units
Volts
Volts
***With ripple satisfying the following conditions: dv/dt
≤ ±5v/µs,
Variation
≤
2V peak to peak.
4