Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PM75DSA120
Intellimod™ Module
Single Phase IGBT Inverter Output
75 Amperes/1200 Volts
Electrical and Mechanical Characteristics,
T
j
= 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ.
Max.
Units
Control Sector
Over Current Trip Level Inverter Part
Short Circuit Trip Level Inverter Part
Over Current Delay Time
Over Temperature Protection
OC
SC
t
off(OC)
OT
OT
R
Supply Circuit Under Voltage Protection
UV
UV
R
Supply Voltage
Circuit Current
V
D
I
D
V
CIN(on)
V
CIN(off)
f
PWM
I
FO(H)
I
FO(L)
Minimum Fault Output Pulse Width
SXR Terminal Output Voltage
t
FO
V
SXR
-20°C
≤
T
≤
125°C
-20°C
≤
T
≤
125°C
V
D
= 15V
Trip Level
Reset Level
Trip Level
Reset Level
Applied between V
P1
-V
PC
, V
N1
-V
NC
V
D
= 15V, V
CIN
= 5V, V
N1
-V
NC
V
D
= 15V, V
CIN
= 5V, V
XP1
-V
XPC
Input ON Threshold Voltage
Input OFF Threshold Voltage
PWM Input Frequency
Fault Output Current
Applied between
C
P1
-V
PC
, C
N1
-V
NC
3-
Sinusoidal
V
D
= 15V, V
FO
= 15V
V
D
= 15V, V
FO
= 15V
V
D
= 15V
T
j
≤125°C,
Rin = 6.8 k
(S
PR
, S
NR
)
105
150
—
100
85
11.5
—
13.5
—
—
1.2
1.7
—
—
—
1.0
4.5
170
250
5
110
95
12.0
12.5
15
13
13
1.5
2.0
15
—
10
1.8
5.1
—
—
—
120
105
12.5
—
16.5
20
20
1.8
2.3
20
0.01
15
—
5.6
Amperes
Amperes
µS
°C
°C
Volts
Volts
Volts
mA
mA
Volts
Volts
kHz
mA
mA
mS
Volts
643