PS21246-E
Intellimod™ Module
Dual-In-Line Intelligent Power Module
25 Amperes/600 Volts
Electrical and Mechanical Characteristics,
T
j
= 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ.
Max.
Units
Control Sector
Supply Voltage
V
D
V
DB
Circuit Current
I
D
Applied between V
P1
-V
PC
, V
N1
-V
NC
Applied between V
UFB
-V
UFS
,
V
VFB
-V
VFS
, V
WFB
-V
WFS
V
D
= 15V, V
CIN
= 5V, V
DB
= 15V,
Total of V
P1
-V
PC
, V
N1
-V
NC
V
D
= 15V, V
CIN
= 5V, V
DB
= 15V,
V
UFB
-V
UFS
, V
VFB
-V
VFS
, V
WFB
-V
WFS
Fault Output Voltage
V
FOH
V
FOL
V
FO(sat)
PWM Input Frequency
Allowable Dead Time
f
PWM
t
DEAD
V
SC(ref)
UV
DBt
UV
DBr
UV
Dt
UV
Dr
Fault Output Pulse Width**
ON Threshold Voltage (H-side)
OFF Threshold Voltage (H-side)
ON Threshold Voltage (L-side)
OFF Threshold Voltage (L-side)
t
FO
V
th(on)
V
th(off)
V
th(on)
V
th(off)
Applied between U
N
, V
N
, W
N
-V
NC
V
SC
= 0V, F
O
Circuit: 10k
to 5V Pull-up
V
SC
= 1V, F
O
Circuit: 10k
to 5V Pull-up
V
SC
= 1V, I
FO
= 15mA
T
C
100°C, T
j
125°C
Relates to Corresponding Input Signal for
Blocking Arm Shoot-through (-20°C
T
C
100°C)
Short Circuit Trip Level*
Supply Circuit Under-voltage
T
j
= 25°C, V
D
= 15V*
Trip Level, T
j
125°C
Reset Level, T
j
125°C
Trip Level, T
j
125°C
Reset Level, T
j
125°C
C
FO
= 22nF
Applied between U
P
, V
P
, W
P
-V
PC
0.45
10.0
10.5
10.3
10.8
1.0
0.8
2.5
0.8
2.5
0.5
1.8
1.4
3.0
1.4
3.0
0.55
12.0
12.5
12.5
13.0
2.0
4.0
2.0
4.0
Volts
Volts
Volts
Volts
Volts
mS
Volts
Volts
Volts
Volts
4.9
0.8
2.5
0.8
1.2
5
1.2
1.8
Volts
Volts
Volts
kHz
µS
1.00
mA
8.50
mA
13.5
13.5
15.0
15.0
16.5
16.5
Volts
Volts
* Short Circuit protection is functioning only at the low-arms. Please select the value of the external shunt resistor such that the SC trip level is less than 25.5A.
**Fault signal is asserted when the low-arm short circuit or control supply under-voltage protective functions operate. The fault output pulse-width t
FO
depends on the capacitance value of
C
FO
according to the following approximate equation: C
FO
= (12.2 x 10
-6
) x t
FO
{F} .
4