Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PS21865-P
Intellimod™ Module
Dual-In-Line Intelligent Power Module
20 Amperes/600 Volts
Electrical and Mechanical Characteristics,
T
j
= 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ.
Max.
Units
Control Sector
Supply Voltage
V
D
V
DB
Circuit Current
I
D
Applied between V
P1
-V
PC
, V
N1
-V
NC
Applied between V
UFB
-V
UFS
,
V
VFB
-V
VFS
, V
WFB
-V
WFS
V
D
= V
DB
= 15V, V
IN
= 5V,
Total of V
P1
-V
PC
, V
N1
-V
NC
V
D
= V
DB
= 15V, V
IN
= 0V,
Total of V
P1
-V
PC
, V
N1
-V
NC
V
D
= V
DB
= 15V, V
IN
= 5V,
V
UFB
-V
UFS
, V
VFB
-V
VFS
, V
WFB
-V
WFS
V
D
= V
DB
= 15V, V
IN
= 0V,
V
UFB
-V
UFS
, V
VFB
-V
VFS
, V
WFB
-V
WFS
Fault Output Voltage
Input Current
Short-Circuit Trip Level*
Supply Circuit Undervoltage
Protection
V
FOH
V
FOL
I
IN
V
SC(ref)
UV
DBt
UV
DBr
UV
Dt
UV
Dr
Fault Output Pulse Width**
ON Threshold Voltage
OFF Threshold Voltage
t
FO
V
th(on)
V
th(off)
V
SC
= 0V, F
O
Circuit: 10kΩ to 5V Pull-up
V
SC
= 1V, I
FO
= 1mA
V
IN
= 5V
T
j
= 25°C, V
D
= 15V
Trip Level, T
j
≤
125°C
Reset Level, T
j
≤
125°C
Trip Level, T
j
≤
125°C
Reset Level, T
j
≤
125°C
C
FO
= 22nF
Applied between U
P
, V
P
, W
P
-V
PC,
U
N
, V
N
, W
N
-V
NC
4.9
—
1.0
0.43
10.0
10.5
10.3
10.8
1.0
2.1
0.8
—
—
1.50
0.48
—
—
—
—
1.8
2.3
1.4
—
0.95
2.00
0.53
12.0
12.5
12.5
13.0
—
2.6
2.1
Volts
Volts
mA
Volts
Volts
Volts
Volts
Volts
ms
Volts
Volts
—
—
0.55
mA
—
—
0.40
mA
—
—
7.00
mA
—
—
5.00
mA
13.5
13.0
15.0
15.0
16.5
18.5
Volts
Volts
Thermal Characteristics
Characteristic
Junction to Fin
Thermal Resistance
Symbol
R
th(j-f)Q
R
th(j-f)D
Condition
IGBT Part (Per 1/6 Module)
FWDi Part (Per 1/6 Module)
Min.
—
—
Typ.
—
—
Max.
1.90
3.00
Units
°C/Watt
°C/Watt
Recommended Conditions for Use
Characteristic
Supply Voltage
Control Supply Voltage
Symbol
V
CC
V
D
V
DB
Control Supply Variation
PWM Input Frequency
ΔV
D
,
ΔV
DB
f
PWM
T
f
≤
100°C, T
j
≤
125°C
Condition
Applied between P-N Terminals
Applied between V
P1
-V
PC
, V
N1
-V
NC
Applied between V
UFB
-V
UFS
,
V
VFB
-V
VFS
, V
WFB
-V
WFS
-1
—
—
—
1
20
V/µs
kHz
Min.
0
13.5
13.0
Typ.
300
15.0
15.0
Max.
400
16.5
18.5
Units
Volts
Volts
Volts
* Short-Circuit protection is functioning only at the lower arms. Please select the value of the external shunt resistor such that the SC trip level is less than 34A.
**Fault signal is asserted when the lower arm short circuit or control supply under-voltage protective functions operate. The fault output pulse-width t
FO
depends on the capacitance value
of C
FO
according to the following approximate equation: C
FO
= (12.2 x 10
-6
) x t
FO
{F} .
4