Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PS21963-4, PS21963-4A, PS21963-4C
Intellimod™ Module
Dual-In-Line Intelligent Power Module
10 Amperes/600 Volts
Thermal Characteristics
Characteristic
Junction to Case
Symbol
R
th(j-c)Q
R
th(j-c)D
Condition
Inverter IGBT (Per 1/6 Module)
Inverter FWDi (Per 1/6 Module)
Min.
—
—
Typ.
—
—
Max.
3.7
4.5
Units
°C/Watt
°C/Watt
Recommended Conditions for Use
Characteristic
Supply Voltage
Control Supply Voltage
V
D
V
DB
Control Supply Variation
Arm Shoot-through Blocking Time
Allowable Minimum Input
Pulse Width*
V
NC
Voltage Variation
dV
D
, dV
DB
t
DEAD
P
WIN(on)
P
WIN(off)
V
NC
Between V
NC
-N (Including Surge)
For Each Input Signal, T
C
≤
100°C
Symbol
V
CC
Condition
Applied between P-N Terminals
Applied between V
P1
-V
NC
, V
N1
-V
NC
Applied between V
UFB
-U,
V
VFB
-V, V
WFB
-W
-1
1.5
0.5
0.5
-5.0
—
—
—
—
—
1
—
—
—
5.0
V/µs
µs
µs
µs
Volts
Min.
0
13.5
13.0
Typ.
300
15.0
15.0
Value
400
16.5
18.5
Units
Volts
Volts
Volts
*DIP-IPM might not make response or work properly if the input signal plus width is less than the recommended minimum value.
Rev. 03/07