PSMF05
thru
PSMF24
APPLICATION NOTE
The PSMF Series are TVS arrays designed to protect I/O or data lines from the damaging effects of ESD or EFT. This product provides unidirectional
protection, with a surge capability of 200 Watts P
PP
per line for an 8/20µs waveform and ESD protection > 25 kilovolts.
UNIDIRECTIONAL COMMON-MODE CONFIGURATION (Figure 1)
The PSMF Series provides up to four (4) lines of protection in a common-mode configuration as depicted in Figure 1.
Circuit connectivity is as follows:
I/O 1 is connected to Pin 1.
I/O 2 is connected to Pin 3.
I/O 3 is connected to Pin 4.
I/O 4 is connected to Pin 5.
Pin 2 is connected to ground.
Figure 1 - Unidirectional Configuration
Common-Mode I/O Port Protection
I/O 4
I/O 3
CIRCUIT BOARD LAYOUT RECOMMENDATIONS
Circuit board layout is critical for Electromagnetic
Compatibility (EMC) protection. The following
guidelines are recommended:
I/O INTEGRATED CIRCUIT
5
4
The protection device should be placed near the
input terminals or connectors, the device will
divert the transient current immediately before it
can be coupled into the nearby traces.
The path length between the TVS device and
the protected line should be minimized.
All conductive loops including power and ground
loops should be minimized.
The transient current return path to ground
should be kept as short as possible to reduce
parasitic inductance.
Ground planes should be used whenever
possible. For multilayer PCBs, use ground vias.
1
I/O 2
I/O 1
2
3
05123.R10 3/07
4
www.protekdevices.com