Displays
ANDpSi08C351-HB
Timing Specifications
Item
Symbol
Min
Typ
Max
Unit
Frame
Period
604 x t3
–
625 x t3
17.78
628 x t3
17.86
–
ms
t1
t2
t3
t4
Vertical
Display Term
600 x t3
600 x t3
600 x t3
t2 = N •t3
One Line Scanning
Time
944 x t5
(26.3)
1056 x t5
26.4
1064 x t5
–
µs
Horizontal Display
Period
800 x t5
800 x t5
800 x t5
–
Clock Period
Clock “L” Time
Clock “H” Time
Set Up Time
Hold Time
t5
t6
t7
t8
t9
24.7
9.0
9.0
4.0
5.0
25.0
27.8
ns
ns
ns
ns
ns
–
–
–
–
–
–
–
–
Timing Chart
t 1
t 2
Vertical Timing
NCLK
t 3
t 3
ENAB
R5 ~ R0
G5 ~ G0
B5 ~ B0
X,1 X,2 X,3 X,4
X,Y
X,598 X,599 X,600
t 3
Horizontal Timing
t 4
t 5
NCLK
ENAB
797,Y 799,Y
798,Y 800,Y
R5 ~ R0
G5 ~ G0
B5 ~ B0
1,Y 2,Y 3,Y 4,Y 5,Y 6,Y 7,Y
X,Y
t 5
t 6 t 7
a
b
V
V
(min) : 0.8 (V)
(max) : 0.2 (V)
IH
NCLK
0.5VDD
Duty (a,b) : 50±10%
NCLK
IL
t 8
VALID
DATA
t 9
Input Signal Center Level : 0.5 V
DD
ENAB
V
IH
V
IL
(min) : 0.8 (V)
(max) : 0.2 (V)
R5 ~ R0
G5 ~ G0
B5 ~ B0
Purdy Electronics Corporation • 720 Palomar Avenue • Sunnyvale, CA 94085
Tel:408.523.8200 • Fax:408.733.1287 • sales@purdyelectronics.com
www.purdyelectronics.com
7/20/07
3