欢迎访问ic37.com |
会员登录 免费注册
发布采购

QGKF-320 参数 Datasheet PDF下载

QGKF-320图片预览
型号: QGKF-320
PDF下载: 下载PDF文件 查看货源
内容描述: 320Watts单路输出 [320Watts Single Output]
分类和应用:
文件页数/大小: 2 页 / 1334 K
品牌: QUALTEK [ QUALTEK ELECTRONICS CORPORATION ]
 浏览型号QGKF-320的Datasheet PDF文件第2页  
320Watts Single Output
Q
ualtek
P
P C
Electronics Corporation
QGKF-320 Series
Features:
Universal AC input/ Full range
Built-in active PFC function, PF>0.95
High Efficiency, and High Reliability
Output Protections: OLP/OPP/SCP
Withstand 300VAC Surge Input for 5 Sec
Operating Altitude up to 5000m
Wide operating ambient temperature (-25°C~70°C)
Conformal Coating on both sides of PCB
All using 105°C long life electrolytic capacitors.
100% full load burn-in test
CB
Model
DC Output
Rated Current
Current Range
(Note 1)
(Note 2)
QGKF-320-5
5V
55A
0~55A
<150mV
±1.0%
±0.5%
±1.0%
QGKF-320-12
12V
25A
0~25A
<150mV
QGKF-320-24
24V
13A
0~13A
<200mV
QGKF-320-48
48V
6.7A
0~6.7A
<200mV
Output Characteristics
Ripple and Noise
Voltage Accuracy
Line Regulation
Load Regulation
Set-up Time
Hold-up Time
Voltage ADJ. Range
-5% ~ +10% of rated output voltage
<2.0s (230VAC input, full load)
>10ms (230VAC input, full load)
±0.03%/°C
<5.0%
85VAC~264VAC, 120VDC~370VDC
47Hz-63Hz
PF>0.98/115VAC PF>0.95/230VAC
79%
<4.5A
<30A@115VAC Cold start <50A@230VAC Cold start
Input-Output: <0.25mA Input-PG: <1.0mA
105%~150% of rated output current, hiccup mode, auto recovery
105%~150% of rated output power, hiccup mode, auto recovery
Long-term mode, auto recovery
-25°C~70°C; 20%~90% RH Non-Condensing
-40°C~85°C: 10%-95% RH Non-Condensing
10 ~500Hz, 2G 10min/1cycle, period for 60min. Each along X, Y, Z axes
UL60950-1 2nd Ed; IEC 60950-1:2005(2nd Ed); EN60950-1: 2006
Primary-Secondary: 3.0KVAC;≤10mA. Primary-PG: 1.5KVAC;≤10mA. Secondary-PG: 0.5KVDC;≤10mA
≥100M ohms
Compliance to EN55022, EN55024 Class B
Compliance to EN61000-3-2, -3
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11; EN55024, EN61000-6-2 heavy industry level
More than 200,000Hrs (25°C, Full load)
199x99x50mm
12PCS/CTN. G.W: 9.8kgs
Cooling by forced air (built-in DC fan)
1. All parameters NOT specially mentioned are measured at rated input, rated load, and 25°C of ambient temperature
2. Measured at 20MHz of bandwith by using a 12” Twisted pair wire terminated with a 0.1uF & 47uF parallel capacitor
3. The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.
Temperature Coefficient
Overshoot and Undershoot
Input Characteristics
Voltage Range
Frequency Range
Power Factor (Typical)
Efficiency (Typical)
AC Current (max)
Inrush Current (Typical)
Leakage Current
84.5%
87%
87.5%
Protection
Over Load (OLP)
Over Power (OPP)
Short Circuit (SCP)
Operating Amb. Temp. & Hum
Storage Temp. & Hum
Vibration
Safety Standards
Withstand Voltage
Isolation Resistance
EMI Conduction & Radiation
Harmonic Current
EMS Immunity
MTBF (MIL-HDBK-217F)
Dimension (LxWxH)
Packing
Cooling Method
Note
Environmental Characteristics
General Characteristics
Page 1 of 2