EW
N
Issue 1, 16 October 2007
Radiometrix
Hartcran House, 231 Kenton Lane, Harrow, HA3 8RP, England
Tel: +44 (0) 20 8909 9595, Fax: +44 (0) 20 8909 2233
ENT1
12.5kHz Channel
12.5kHz Channel VHF High Power TX
The ENT1 transmitter modules offer a
100mW RF output VHF data link in
Radiometrix SIL standard pin-out and
footprint. This makes the ENT1 ideally
suited to those low power applications
where existing narrow band and
wideband
transmitters
provide
insufficient range. Together with the
matching LMR1/RX1M receiver a one-
way radio data link can be achieved
over a distance up to 10km+ with
suitable choice of data rate and
antennas.
Figure 1: ENTI –169.40625-3
Features
•
•
•
•
•
•
•
•
Conforms to EN 300 220-3 and EN 301 489-3
Standard frequency 169.406250MHz
Other frequencies from 120MHz to 180MHz
12.5 kHz channel spacing
Data rates up to 3kbps
Usable range over 10km
Fully screened
Low power requirements
Applications
•
•
•
•
•
•
•
Remote meter reading
Data loggers
Industrial telemetry and telecommand
In-building environmental monitoring and control
High-end security and fire alarms
DGPS systems
Vehicle data up/download
Technical Summary
•
•
•
•
•
•
Size: 43 x 14.5 x 5mm
Operating frequency: 169.406250MHz
Supply range: 5v
Current consumption: 70mA Max
Data bit rate: 3kbps max.
Transmit power: 20dBm (100mW) nominal
Radiometrix Ltd.,
ENT1 high power transmitter data sheet
Page 1