欢迎访问ic37.com |
会员登录 免费注册
发布采购

RPM1-173.250-3-HP 参数 Datasheet PDF下载

RPM1-173.250-3-HP图片预览
型号: RPM1-173.250-3-HP
PDF下载: 下载PDF文件 查看货源
内容描述: 甚高频电台分组调制解调器 [VHF Radio Packet Modem]
分类和应用: 调制解调器
文件页数/大小: 15 页 / 641 K
品牌: RADIOMETRIX [ RADIOMETRIX LTD ]
 浏览型号RPM1-173.250-3-HP的Datasheet PDF文件第4页浏览型号RPM1-173.250-3-HP的Datasheet PDF文件第5页浏览型号RPM1-173.250-3-HP的Datasheet PDF文件第6页浏览型号RPM1-173.250-3-HP的Datasheet PDF文件第7页浏览型号RPM1-173.250-3-HP的Datasheet PDF文件第9页浏览型号RPM1-173.250-3-HP的Datasheet PDF文件第10页浏览型号RPM1-173.250-3-HP的Datasheet PDF文件第11页浏览型号RPM1-173.250-3-HP的Datasheet PDF文件第12页  
F
LOW
default
valid range
S
ERDLY
Sets the serial flow control between the host and RPM1.
Using no flow control enables the RPM1 to be used with a 3 wire serial link (TXD,
RXD, GND). Care must be taken in order to prevent overflowing the 96 byte serial
receive buffer in the RPM1.
Using hardware flow control enables the RPM1 to control the flow of serial data being
received.
none
hw, none
Sets the serial data receive to packet transmit delay.
When the RPM1 receives the first byte of data from the host, it starts a timer running.
Either a full buffer of data to send or a timeout of this timer will allow the packet to be
transmitted.
Fine tuning this delay for the baud rate the RPM1 is operating at can significantly
increase throughput while reducing unnecessary transmissions.
2 (x10ms)
2 to 255 (x10ms)
Sets the action of the W
AKE
input.
Setting shutdown to
O
N
will cause the RPM1 to monitor the
WAKE
input. When
WAKE
is taken high the RPM1 will be forced into low power sleep mode, thus reducing
current consumption. Subsequently lowering the
WAKE
input will bring the RPM1 out
of low power sleep mode.
SHDN should be set to
OFF
or WAKE pin should be pulled Low when the host (DTE)
cannot provide DTR control signal to wake RPM1 in a 3-wire serial interface.
Do not set it to
OFF
for RPM1 Issue 2.
On
on, off
Sets the number of data retry attempts.
RF interference can cause a transmitted data packet to be lost or corrupt on reception.
If this happens the RPM1 will retransmit any unacknowledged transfer. The
transmission will be retried the specified number of times before the link to the
remote unit is considered ‘lost’ and the data purged.
5
1 to 63
Enables the startup message.
The startup message is enabled by default, thus giving an immediate indication of the
operation of the RPM1. The message can be disabled prior to deployment of the RPM1
module.
On
on, off
Enables transfer acknowledgements.
This function enables packet transfer acknowledgements to be returned for every
outgoing packet. Packet acknowledgements aid in the delivery of error free and
consistent data transfers between a pair of modems. Disabling the acknowledgements
results in higher data throughput between modems, but does not protect against lost
data due to RF interference. It should be disabled while using RPM1 in a broadcast
mode. Do not set it to
ON
for RPM1T and RPM1R as they cannot establish connection.
On
on, off
Enables remote configuration.
Over-air remote configuration of a RPM1 module is possible once it has been enabled.
The remote command is used to send remote configuration commands. See the
following chapter for a overview of remotely configuring a RPM1 module.
Off
on, off
Starts the radar test.
Used as a range or confidence test between RPM1 modules within the same
site.
Unit number between 0 and 15.
VHF Narrow Band FM Radio Packet Modem
page 8
default
valid range
S
HDN
default
valid range
R
ETRY
default
valid range
S
TRTMSG
default
valid range
A
CKMODE
default
valid range
R
EMOTE
default
valid range
R
ADAR
parameter
Radiometrix Ltd.