Features
Regulated
Converters
●
●
●
●
●
●
●
Compact High Voltage Power Supplies
5 Watt in Low Profile DIP24 Package
3000VDC Isolation
Remote Voltage Programming by External
Voltage or Resistance
Continuous Short Circuit Protection
Cascadeable to generate Output Voltages of
up to 420VDC
Efficiency to 86%
INNOLINE
DC/DC-Converter
Rxx-
100_150A
Series
5 Watt
Single
Output
Selection Guide
Part
Number
DIP 24
R12-100A
R15-100A
R24-100A
R12-150A
R15-150A
R24-150A
Input
Range
(VDC)
12 ( 10 – 14 )
15 ( 13 – 17 )
24 ( 21 – 27 )
12 ( 10 – 14 )
15 ( 13 – 17 )
24 ( 21 – 27 )
Output
Voltage (1)
(VDC)
+55...+135
+55...+135
+55...+135
+95...+210
+95...+210
+95...+210
Output
Current (2)
(mA)
50
50
50
50
50
50
Notes:
1. Adjustable with external voltage 0 to +4VDC or with 5k. variable resistor. See below for details.
2. Maximum Power Dissipation is 5W.
Specifications
( typical at 25°C, nominal input voltage, rated output current unless otherwise specified )
Input Voltage Range
Rated Power
Voltage Adjustment Range ( see note 1 )
Minimum Load for proper regulation
Output Voltage Accuracy
Line Voltage Regulation
Load Voltage Regulation ( 20% to 100% full load )
Output Ripple and Noise (20MHz limited)
Operating Frequency
Efficiency at Full Load
Isolation Voltage (tested for 1 second)
Isolation Capacitance
Isolation Resistance
Short Circuit Protection
Short Circuit Input Current
Operating Temperature Range (free air convection, with derating)
Storage Temperature Range
MTBF
www.recom-international.com
10..14 or 13..17 or 21..27VDC
50mA max. or 5 Watts max.
55..135 or 95..210VDC
10mA
±5% max
0.2% max
0.3% max
100mVp-p max.
200kHz typ.
Output Power (%)
125
100
60
75
50
25
Derating Graph
(Ambient Temperature)
80 ~ 86%
3000VDC min.
20pF typ.
1 MΩ min.
Continuous, Automatic Restart
30mA typ.
-25°C to +85°C
-50°C to +125°C
1635 x 10³hours min.
February-2007
Natural Convection
0
-25
-10 0
50 60 70
65
80 90 100
Ambient Temperature Range (°C)
175