Features
Unregulated
Converters
●
●
●
●
●
●
●
Dual Output from a Single Input Rail
1kVDC & 2kVDC Isolation
Power Sharing on Output
Optional Continuous Short Circuit Protected
Custom Solutions Available
UL94V-0 Package Material
Efficiency to 86%
ECONOLINE
DC/DC-Converter
RD
&
RC
Series
2 Watt
SIP7
&
DIP14
Dual Output
Selection Guide
Part
Number
SIP 7
RD-xx3.3D
RD-xx05D
RD-xx09D
RD-xx12D
RD-xx15D
Input
Voltage
(VDC)
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
Output
Voltage
(VDC)
±3.3
±5
±9
±12
±15
Output
Current
(mA)
±303
±200
±111
±84
±66
Efficiency
(%)
75
75-82
80-84
80-84
82-86
82-86
DIP 14
2kV
RC-xx3.3D (H)
RC-xx05D (H)
RC-xx09D (H)
RC-xx12D (H)
RC-xx15D (H)
RD-xx24D
RC-xx24D (H)
5, 9, 12, 15, 24
±24
±42
xx = Input Voltage
* add Suffix “P” for Continuous Short Circuit Protection, e.g. RD-0505D/P, RD-0505D/HP
Specifications
(Core Operating Area)
Input Voltage Range
Output Voltage Accuracy
Line Voltage Regulation
Load Voltage Regulation
(10% to 100% full load)
Output Ripple and Noise (20MHz limited)
Operating Frequency
Efficiency at Full Load
No Load Power Consumption
Isolation Voltage
Rated Working Voltage
Isolation Voltage
Rated Working Voltage
Isolation Capacitance
Isolation Resistance
Short Circuit Protection
P-Suffix
Operating Temperature Range (free air convection)
Storage Temperature Range
Relative Humidity
Package Weight
MTBF (+25°C)
(+85°C)
H-Suffix
H-Suffix
3.3V output types
5V output type
9V, 12V, 15V, 24V output types
±10%
±5%
1.2%/1% of Vin typ.
20% max.
15% max.
10% max.
150mVp-p max.
34kHz min. / 50kHz typ. / 85kHz max.
70% min. / 80% typ.
163mW min. / 223mW typ. / 350mW max.
(tested for 1 second)
1000VDC min.
(long term isolation)
see Application Notes.
(tested for 1 second)
(long term isolation)
2000VDC min.
see Application Notes
40pF min. / 115pF max.
Output Power (%)
Derating-Graph
(Ambient Temperature)
100
80
60
40
20
0
-40
0
50
100
150
10 GΩ min.
1 Second
Continuous
-40°C to +85°C (see Graph)
-55°C to +125°C
95% RH
2.8g
using MIL-HDBK 217F
using MIL-HDBK 217F
988 x 10
3
hours
135 x 10
3
hours
Safe Operating Area
85
Operating Temperature °C
}
Detailed Information see
Application Notes chapter "MTBF"
73