ECONOLINE - DC/DC-Converter
RI Series, 2 Watt, SIP4 (Single Output)
Features
●
●
●
1kVDC Isolation
No Heatsink Required
No Extern. Components Required
●
●
●
Custom Solutions Available
UL94V-0 Package Material
Efficiency to 80%
Selection Guide
Part
Number
SIP4
RI-XX3.3
RI-XX05
RI-XX07
RI-XX09
RI-XX12
RI-XX15
RI-XX24
Input
Voltage
(VDC)
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
5, 9, 12, 15, 24
Output
Voltage
(VDC)
3.3
5
7
9
12
15
24
Output
Current
(mA)
606
400
285
222
168
132
83
Efficiency
(%)
70
75
72
76
78
80
80
Specifications (Core Operating Area) and Operating Temperature / Derating-Graph
Input Voltage
Input Filter
Output Voltage Accuracy
Line Voltage Regulation
Load Voltage Regulation
(10% to 100% full load)
Efficiency at Full Load
Isolation Voltage
Isolation Resistance (Viso = 500VDC)
Isolation Capacitance
Short Circuit Protection
Switching Frequency at Full Load
Operating Temperature
Storage Temperature
Package Weight
3.3V output type
5V output type
7V, 9V, 12V, 15V, 24V output types
±10%
Capacitor Type
±5%
1,2%/1% V Input
20% max.
15% max.
10% max.
70% min.
1.000VDC min.
10 GΩ min.
30pF min./85pF max.
1 Second
35kHz min. / 85kHz max.
–40°C to +85°C (see Graph)
-55°C to +125°C
1.4g
4.0
3.0
Output Power (Watts)
2.0
Safe Operating Area
1.0
0
-40
0
50
100
125
150
85
Operating Temperature ˚C
www.recom-international.com
August 2002
EC 51