Features
Unregulated
Converters
Selection Guide
Part
Number
DIP 14
RJ-xx1.8S
RJ-xx3.3S
RJ-xx05S
RJ-xx09S
RJ-xx12S
RJ-xx15S
RJ-xx24S
RG-xx1.8D
RG-xx3.3D
RG-xx05D
RG-xx09D
RG-xx12D
RG-xx15D
RG-xx24D
4kV
(H)
(H)
(H)
(H)
(H)
(H)
(H)
(H)
(H)
(H)
(H)
(H)
(H)
(H)
●
●
●
●
●
●
Dual Output from a Single Input Rail
3kVDC & 4kVDC Isolation
Optional Continuous Short Circuit Protected
Custom Solutions Available
UL94V-0 Package Material
Efficiency to 84%
ECONOLINE
DC/DC-Converter
RJ
&
RG
Series
1 Watt
DIP14
Single
&
Dual
Output
Input
Voltage
(VDC)
1.8, 3.3, 5, 9, 12, 15, 24
1.8, 3.3, 5, 9, 12, 15, 24
1.8, 3.3, 5, 9, 12, 15, 24
1.8, 3.3, 5, 9, 12, 15, 24
1.8, 3.3, 5, 9, 12, 15, 24
1.8, 3.3, 5, 9, 12, 15, 24
1.8, 3.3, 5, 9, 12, 15, 24
1.8, 3.3, 5, 9, 12, 15, 24
1.8, 3.3, 5, 9, 12, 15, 24
1.8, 3.3, 5, 9, 12, 15, 24
1.8, 3.3, 5, 9, 12, 15, 24
1.8, 3.3, 5, 9, 12, 15, 24
1.8, 3.3, 5, 9, 12, 15, 24
1.8, 3.3, 5, 9, 12, 15, 24
Output
Voltage
(VDC)
1.8
3.3
5
9
12
15
24
±1.8
±3.3
±5
±9
±12
±15
±24
Output
Current
(mA)
303
303
200
111
84
66
42
±152
±152
±100
±56
±42
±33
±21
Efficiency
(%)
70
75
70-78
78-82
78-82
78-82
74-83
70
70
70-78
75-80
78-84
80-84
80-84
xx = Input Voltage
* add Suffix “P” for Continuous Short Circuit Protection, e.g.
RJ-0505S/P, RG-0505D/HP
EN-60950-1 Certified
EN-60601-1 Certified
Specifications
(Core Operating Area)
Input Voltage Range
Output Voltage Accuracy
Line Voltage Regulation
Load Voltage Regulation
(10% to 100% full load)
Output Ripple and Noise (20MHz limited)
Operating Frequency
Efficiency at Full Load
No Load Power Consumption
Isolation Voltage
Rated Working Voltage
Isolation Voltage
Rated Working Voltage
Isolation Capacitance
Isolation Resistance
Short Circuit Protection
P-Suffix
Operating Temperature Range (free air convection)
Storage Temperature Range
Relative Humidity
Package Weight
H-Suffix
H-Suffix
(tested for 1 second)
(long term isolation)
(tested for 1 second)
(long term isolation)
±10%
±5%
1.2%/1% of Vin typ.
1.8V, 3.3V output types
20% max.
5V output type
15% max.
9V, 12V, 15V, 24V output types
10% max.
100mVp-p max.
57kHz min. / 90kHz typ. / 105kHz max.
70% min. / 80% typ.
102mW min./180mW typ./260mW max.
3000VDC min.
see Application Notes.
4000VDC min.
see Application Notes
Output Power (%)
100
80
60
40
30
20
0
Derating-Graph
(Ambient Temperature)
20pF min. / 65pF max.
15 GΩ min.
1 Second
Continuous
-40°C to +85°C (see Graph)
-55°C to +125°C
95% RH
2.5g
continued on next page
Safe Operating Area
85
Operating Temperature °C
-40
0
50
100
150
www.recom-international.com
July-2006
35