M66310P/FP
Electrical Characteristics
(VCC = 4.5 to 5.5 V, unless otherwise noted)
Limits
Ta = 25°C
Typ
Ta = −40 to +85°C
Min Max
0.7×VCC 0.35×VCC 0.7×VCC
Item
Symbol
Unit
Conditions
Min
Max
Positive-
going
VT
0.35×VCC
—
V
V
O = 0.1V, VCC–0.1V IO = 20 µA
+
threshold
voltage
Negative- VT–
going
threshold
voltage
0.2×VCC
—
0.55×VCC 0.2×VCC 0.55×VCC
V
V
V
V
V
O = 0.1V, VCC–0.1V IO = 20 µA
High-level VOH
output
voltage
VCC−0.1
3.83
—
—
—
—
—
—
V
CC−0.1
3.66
—
—
—
VI = VT , VT−
I
I
I
OH = −20 µA
+
VCC = 4.5 V
OH = −24 mA
OH = −40 mA (Note)
3.50
3.25
QA to QP
High-level VOH
output
voltage
VCC−0.1
—
—
—
—
V
CC−0.1
—
—
VI = VT , VT–
I
I
OH = −20 µA
OH = −4 mA
+
VCC = 4.5 V
3.83
3.66
SQP
Low-level
output
voltage
SQP
VOL
—
—
—
—
0.1
—
—
0.1
VI = VT , VT
I
I
OL = 20 µA
OL = 4 mA
+
−
VCC = 4.5 V
0.44
0.53
High-level IIH
input
current
—
—
—
—
0.5
—
—
5.0
µA
µA
µA
VI = VCC, VCC = 5.5 V
VI = GND, VCC = 5.5 V
Low-level
input
IIL
−0.5
−5.0
current
Maximum IO
output
—
—
—
—
1.0
—
—
10.0
VI = VT , VT
VO = VCC
+
−
VCC = 5.5 V
−1.0
−10.0
VO = GND
leakage
current
QA to QP
Quiescent ICC
supply
—
—
20.0
—
200.0
µA
VI = VCC, GND, VCC = 5.5 V
current
Note: M66310 is used under the condition of an output current IOH = −40 mA, the number of simultaneous drive outputs
are restricted as shown in the Duty Cycle-IOH of Standard characteristics.
REJ03F0176-0201 Rev.2.01 Mar 31, 2008