2F8722DS
2F8722DSM
CATV Line Amplifier
Bandwidth 45 to 870MHz; VCC = 24V; Tcase = 25℃; ZS = ZL = 75Ω
Characteristics
SYMBOL
PARAMETER
CONDITIONS
MIN
TYP MAX UNIT
f = 45 MHz
21.5
21.8
22.5
dB
dB
Gp
Power gain
f = 870 MHz
22.5
23.0
-
-
SL
FL
Slope cable equivalent
f = 45 to 870 MHz
f = 45 to 870 MHz
-
-
1.0
dB
dB
Flatness of frequency response
-
-
-
-
-
0.5
-
f = 45 to 80 MHz
f = 80 to 160 MHz
20.0
20.0
dB
dB
-
f = 160 to 320 MHz
f = 320 to 640 MHz
19.0
18.0
dB
dB
-
S11
Input return loss
-
f = 640 to 870 MHz
18.0
dB
-
-
-
f = 45 to 80 MHz
f = 80 to 160 MHz
20.0
20.0
-
dB
dB
-
-
f = 160 to 320 MHz
f = 320 to 640 MHz
f = 640 to 870 MHz
19.0
18.0
18.0
dB
dB
dB
S22
Output return loss
-
-
-
-
-
-
f = 45 MHz
f = 550 MHz
f = 750 MHz
f = 860 MHz
-
4.5
4.9
5.1
5.3
400
-
dB
dB
dB
dB
mA
-
-
-
-
F
Noise Figure
-
-
Itot
Total current consumption (DC)
380
420
Bandwidth 45 to 870MHz; VCC = 24V; Tcase = 25℃; ZS = ZL = 75Ω
Distortion
SYMBOL
PARAMETER
CONDITIONS
MIN
TYP MAX UNIT
CTB
Composite triple beat
Cross modulation
135 channel flat; Vo =+48dBmV
135 channel flat; Vo = +48dBmV
135 channel flat; Vo = +48dBmV
-
-
-
-61
-60
-65
-55
-57
-58
dBc
dBc
dBc
XMOD
CSO
Composite second order distortion
Notes;
135 Channels, NTSC frequency raster: 55.25MHz to 859.25MHz, +48dBmV flated output level.
CTB, XMOD, CSO definitions follow NCTA definition
ESD Protection
Gallium Arsenide Integrated Circuits are sensitive to electrostatic discharge (ESD) and can be damaged by static electricity.
Proper ESD control techniques should be used when handling these devices. Some of the precautions recommended are;
- Person at a workbench should be earthed via a wrist strap and a resistor.
- All mains-powered equipment should be connected to the mains via an earth-leakage switch.
- Equipment cases should be grounded.
- Relative humidity should be maintained between 40% and 50%.
- An ionizer is recommended.
- Keep static materials, such as plastic envelopes and plastic trays etc. away from the workbench.
▪ Tel : 82-31-250-5011
▪ rfsales@rfhic.com
▪ All specifications may change without notice.
▪ Version 5.4