Turns Ratio ( + 5% )
1CT :1CT
MULTI-PURPOSE
PULSE
TRANSFORMER
Flammability: Materials used in
the production of these units
meet requirements of UL94-VO
and IEC 695-2-2 needle flame
test.
PARAMETER
Open Circuit Inductance
Leakage Inductance
Interwinding Capacitance (C
W/W
)
Primary DC Resistance
Secondary DC Resistance
Primary ET-Constant
Rise Time
Isolation (HI-POT)
Average Power Rating
Dissipation Rating
Peak Pulse Voltage
Insulation Resistance
TEST CONDITIONS:
MIN.
5000
MAX.
UNITS
µHy
1.3
60
3.9
3.9
25
10.5
500
500 mW
150 mW
100 volts
10,000 MΩ
µHy
pF
ohms
ohms
Vµs
nS
V
RMS
Parts shipped in anti-static
tubes. 44 pieces per tube
SCHEMATIC DIAGRAM
Oscillation Voltage = 20mV
Oscillation Frequency = 100.0 KHz TESTED WITH AN H.P. 4192A
5
3
6
4
2
PHYSICAL DIMENSIONS
All dimensions in inches (mm)
1
RHOMBUS P/N:
CUST P/N:
DATE: 07/02/98
T-51109
NAME:
SHEET: 1 OF 1
Rhombus
Industries Inc.
Transformers & Magnetic Products
www.rhombus-ind.com
15801 Chemical Lane,
Huntington Beach, CA 92649-1595
Phone: (714) 898-0960 FAX: (714) 896-0971