欢迎访问ic37.com |
会员登录 免费注册
发布采购

RT9162-35PX 参数 Datasheet PDF下载

RT9162-35PX图片预览
型号: RT9162-35PX
PDF下载: 下载PDF文件 查看货源
内容描述: 300mA低压差正电压稳压器 [300mA Low Dropout Positive Voltage Regulator]
分类和应用: 稳压器
文件页数/大小: 5 页 / 79 K
品牌: RICHTEK [ RICHTEK TECHNOLOGY CORPORATION ]
 浏览型号RT9162-35PX的Datasheet PDF文件第1页浏览型号RT9162-35PX的Datasheet PDF文件第2页浏览型号RT9162-35PX的Datasheet PDF文件第4页浏览型号RT9162-35PX的Datasheet PDF文件第5页  
RT9162
Absolute Maximum Ratings
Input Voltage ------------------------------------------------------------------------------------------------------------ 15V
Power Dissipation, P
D
@ T
A
= 25°C
TO-92 --------------------------------------------------------------------------------------------------------------------- 0.625W
SOT-89 ------------------------------------------------------------------------------------------------------------------- 0.571W
Package Thermal Resistance (Note4)
TO-92,
θ
JA
--------------------------------------------------------------------------------------------------------------- 160°C/W
SOT-89,
θ
JA
------------------------------------------------------------------------------------------------------------- 175°C/W
Operating Junction Temperature Range --------------------------------------------------------------------------
40°C to 125°C
Storage Temperature Range ----------------------------------------------------------------------------------------
65°C to 150°C
Electrical Characteristics
(V
IN
= 5.0V, T
A
= 25°C, unless otherwise specified)
Parameter
Output Voltage
Line Regulation
Load Regulation
Dropout Voltage
Current Limit
Quiescent Current
Temperature Coefficient
Temperature Stability
RMS Output Noise
(Note 3)
(Note 1)
(Note 1)
(Note 1)
(Note 2)
RT9162-33
RT9162-35
Symbol
V
OUT
ΔV
LINE
Test Conditions
Min
3.235
3.430
Typ
3.300
3.500
0.1
0.2
1.2
--
4.5
0.005
0.5
0.003
Max
3.365
3.570
0.4
0.4
1.3
--
8
--
--
--
Units
V
%
%
V
mA
mA
%/°C
%
%/V
OUT
V
IN
= 5V–15V
ΔV
OUT
= 1%
--
--
--
400
--
--
--
--
ΔV
LOAD
I
L
= 0 - 300mA
V
DROP
I
LIM
I
Q
T
C
T
S
Note 1.
Low duty cycle pulse testing with Kelvin connections required.
Note 2.
The dropout voltage is defined as V
IN
-V
OUT
, which is measured when V
OUT
is V
OUT(NORMAL)
100mV.
Note 3.
Bandwidth of 10 Hz to 10 kHz.
Note 4.
θ
JA
is measured in the natural convection at T
A
= 25°C on a low effective thermal conductivity test board of
JEDEC 51-3 thermal measurement standard.
DS9162-16 March 2007
www.richtek.com
3