RT9193
Parameter
Power Supply
Rejection Rate
f = 100Hz
f = 10kHz
Symbol
PSRR
T
SD
ΔTSD
Test Conditions
C
OUT
= 1μF, I
OUT
= 10mA
Min
--
--
--
--
Typ
−70
−50
165
30
Max
--
--
--
--
Units
dB
°C
°C
Thermal Shutdown Temperature
Thermal Shutdown Temperature
Note 1.
Stresses listed as the above "Absolute Maximum Ratings" may cause permanent damage to the device. These are for
stress ratings. Functional operation of the device at these or any other conditions beyond those indicated in the
operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended
periods may remain possibility to affect device reliability.
Note 2.
Devices are ESD sensitive. Handling precaution is recommended.
Note 3.
The device is not guaranteed to function outside its operating conditions.
Note 4.
θ
JA
is measured in the natural convection at T
A
= 25°C on a low effective thermal conductivity test board
(Single Layer, 1S) of JEDEC 51-3 thermal measurement standard.
Note 5.
The dropout voltage is defined as V
IN
- V
OUT
, which is measured when V
OUT
is V
OUT(NORMAL)
−
100mV.
www.richtek.com
4
DS9193-11 May 2008