R5321D
OPERATION
R5324DxxxA
V
DD
1
R1_1
Error Amp.
Vref
CE1 2
Current Limit
R2_1
7 N.C.
8 V
OUT1
CE2 3
6 V
OUT2
R1_2
Error Amp.
Vref
N.C. 4
Current Limit
R2_2
5 GND
Fluctuation of each regulator’s output voltage, or V
OUT1
, V
OUT2
is detected individually and put back to an error
amplifier through feedback resistors, or R1_1, R2_1, R1_2, R2_2 and compared with a reference voltage and
compensated for the result and make a constant voltage.
In each regulator, short protection is made by a current limit circuit and stand-by mode is available by a chip
enable circuit.
6