欢迎访问ic37.com |
会员登录 免费注册
发布采购

AS-120P-12 参数 Datasheet PDF下载

AS-120P-12图片预览
型号: AS-120P-12
PDF下载: 下载PDF文件 查看货源
内容描述: 120WAC -DC单路输出台式机 [120WAC-DC Single Output Desktop]
分类和应用:
文件页数/大小: 2 页 / 121 K
品牌: RSG [ RSG ELECTRONIC COMPONENTS GMBH ]
 浏览型号AS-120P-12的Datasheet PDF文件第2页  
ELECTRONIC COMPONENTS
RSG
RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany
Tel. +49 69 984047-0 Fax +49 69 984047-77 info@rsg-electronic.de
www.rsg-electronic.de
Änderungen vorbehalten / subject to change without notice
120W AC-DC Single Output Desktop
Features :
AS-120P
3 pole AC inlet IEC320-C14
Built-in active PFC function, PF>0.95
series
Protections: Short circuit/ Over load/ Over voltage/Over temperature
3
High power density 5w/in
Fully enclosed plastic case
Approvals: UL/ CUL/ TUV/ CB/ CE
No load power consumption<0.75W@240VAC
ZCS/ZVS technology to reduce power dissipation
2 years warranty
R
SPECIFICATION
MODEL
ORDER NO.
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
AS-120P-12
AS120P12R7B
Note.2
12V
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
AS-120P-15
AS120P15R7B
15V
6.7A
0 ~ 6.7A
100W
100mVp-p
13.5 ~ 16.5V
AS-120P-20
AS120P20P1M
20V
6A
0 ~ 6A
120W
200mVp-p
18 ~ 22V
3.0%
1.0%
2.5%
AS-120P-24
AS120P24P1M
24V
5A
0 ~ 5A
120W
200mVp-p
21.6 ~ 26.4V
2.0%
1.0%
2.0%
AS-120P-48
AS120P48P1M
48V
2.5A
0 ~ 2.5A
120W
240mVp-p
43.2 ~ 52.8V
2.0%
1.0%
2.0%
8.4A
0~ 8.4A
100W
11 ~ 13.5V
RIPPLE & NOISE (max.)
Note.3
100mVp-p
VOLTAGE ADJ. RANGE
Fixed output by customer choose
VOLTAGE TOLERANCE
Note.4
4.0%
4.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT (max.)
OVER LOAD
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
Note.5
Note.6
1.0%
3.5%
3000ms, 80ms at full load
50ms/230VAC
90 ~ 264VAC
47 ~ 63Hz
PF
0.95/230VAC
PF
1.0%
3.0%
16ms/115VAC at full load
127 ~ 370VDC
0.98/115VAC at full load
85.5%
1.4A/115VAC
120A/230VAC
<1mA / 240VAC
87.5%
0.7A/230VAC
89.5%
90%
89%
105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
14 ~ 16.8V
22.5 ~ 28V
17 ~ 21V
Protection type : Shut down o/p voltage, re-power on to recover
90
15 (RTH2) Detect on heatsink of power transistor
(Refer to output load derating curve)
Protection type : Shut down o/p voltage, re-power on to recover
0 ~ + 50
20% ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.03% / (0 ~ 50 )
10 ~ 500Hz, 2G 3AXES 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
27 ~ 33.6V
53.3 ~ 67.2V
I/P-O/P:4.25KVDC
SAFETY & ISOLATION RESISTANCE
I/P-O/P:100M Ohms
EMI CONDUCTION & RADIATION
Compliance to EN55022(CISPR22) class B, FCC part 15J class B
EMC
(Note. 7)
HARMONIC CURRENT
EMS IMMUNITY
LIFE
Compliance to EN61000-3-2,3
Compliance to EN61000-4-2,3,4,5,6,8,11, Light industry level, criteria A
Average life expectancy of 6 years (12 hours / day, 70% load, 115VAC)
308.9K hrs min.
MIL-HDBK-217F (25
)
167*67*35mm (L*W*H)
0.52Kg; 30pcs/16.6Kg/1.1CUFT
Standard type R7B,P2M: 2.5 * 5.5 * 11mm, center positive for stock ; Other type available by customer requested
Standard type 120cm of SPT-1, 16Awg*2c for stock ; Other type available by customer requested
OTHERS
MTBF
DIMENSION
PACKING
PLUG
CABLE
CONNECTOR
NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH. Ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerence: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 0% to 100% rated load.
7.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.