欢迎访问ic37.com |
会员登录 免费注册
发布采购

LEA150F-18 参数 Datasheet PDF下载

LEA150F-18图片预览
型号: LEA150F-18
PDF下载: 下载PDF文件 查看货源
内容描述: 坚固型PCB [Rugged PCB type]
分类和应用: PC
文件页数/大小: 2 页 / 135 K
品牌: RSG [ RSG ELECTRONIC COMPONENTS GMBH ]
 浏览型号LEA150F-18的Datasheet PDF文件第2页  
Rugged PCB type
Ordering information
LEA150F
R
LEA 150
1
2
3
F
4
-5
5
-O
1Series
name
2Output
wattage
3Universal
input
4Output
voltage
5Optional
C :with Coating
G :Low leakage current
J2:Mini terminal block
R :with Remote ON/OFF
S :with Chassis
SN :with Chassis & cover
Y :with Potentiometer
Recommended Noise Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The
Noise Filter is recommended
*to
connect with several devices.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
*
5
LEA150F-3R3-Y LEA150F-5 LEA150F-9 LEA150F-12 LEA150F-15 LEA150F-18 LEA150F-24 LEA150F-24-H LEA150F-30 LEA150F-48
99
150
153
150
150
153
151.2
151.2
150
153.6
3.3V 30A
5V 30A
9V 17A
12V 12.5A 15V 10A
18V 8.5A
24V 6.3A
24V 6.3(7.5)A 30V 5A
48V 3.2A
SPECIFICATIONS
LEA
MODEL
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
INPUT
ACIN 100V
ACIN 200V
ACIN 100V
POWER FACTOR
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
*
1
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50
C
*
2
RIPPLE[mVp-p]
-10 - 0
C
*
2
0 to +50
C
*
2
RIPPLE NOISE[mVp-p]
-10 - 0
C
*
2
0 to +50
C
TEMPERATURE REGULATION[mV]
-10 to +50
C
DRIFT[mV]
*
3
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
-
RC
*
4
INPUT-FG
OUTPUT
-
RC-FG
*
4
OUTPUT-RC
*
4
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
EFFICIENCY[%]
ACIN 100V
ACIN 200V
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
LEA150F-3R3-Y LEA150F-5 LEA150F-9 LEA150F-12 LEA150F-15 LEA150F-18 LEA150F-24 LEA150F-24-H
AC85 - 264 1
f
or DC120 - 370
1.4
2.0typ
0.7
1.0typ
50/60 (47 - 63) or DC
71typ
76typ
79typ
78typ
80typ
81typ
81typ
81typ
74typ
79typ
82typ
81typ
83typ
84typ
84typ
84typ
0.98typ
0.99typ
0.91typ
0.94typ
15typ (Io=100%) (At cold start) (Ta=25
C
)
30typ (Io=100%) (At cold start) (Ta=25
C
)
0.75max (60Hz, According to IEC60950 and DEN-AN)
3.3
5
9
12
15
18
24
24
30
30
17
12.5
10
8.5
6.3
6.3 (Peak 7.5)
20max
20max
36max
48max
60max
72max
96max
96max
40max
40max
100max
100max
120max
120max
150max
150max
80max
80max
120max
120max
120max
120max
120max
120max
140max
140max
160max
160max
160max
160max
160max
160max
120max
120max
150max
150max
150max
150max
150max
150max
160max
160max
180max
180max
180max
180max
180max
180max
50max
50max
90max
120max
150max
180max
240max
240max
60max
60max
120max
150max
180max
200max
290max
290max
20max
20max
36max
48max
60max
72max
96max
96max
500max (ACIN 100V, Io=100%)
20typ (Io=100%)
2.85 - 3.6
Fixed ("Y"which can be adjusted the output is available as optional:
t
10%)
3.25 - 3.35 4.9 - 5.3
8.6 - 9.4
11.5 - 12.5 14.4 - 15.6 17.3 - 18.7 23.0 - 25.0 23.0 - 25.0
Works over 105% of rating (works over 105% of peak current at option -H) and recovers automatically
4.00 - 5.25V Works at 115 - 140% of rating
Not provided
Not provided
Option (Refer to Instruction Manual)
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
AC100V 1minute, Cutoff current = 100mA, DC100V 10M
W
min (At Room Temperature)
-10 to +60
C
, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL, EN60950-1, EN50178 Complies with DEN-AN and IEC60950-1 (At only AC input)
Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
Complies with IEC61000-3-2
75
X
40
X
222mm (W
X
H
X
D) /500g max (without chassis and cover)
Convection
*4
*5
*
*
with the input voltage held constant at the rated input/output.
Applicable when remote control (optional) is added.
( ): peak current.
Parallel operation with other model is not possible.
Derating is required when operated with chassis and cover.
LEA150F-30 LEA150F-48
84typ
87typ
84typ
87typ
30
5
120max
180max
120max
160max
150max
180max
300max
360max
120max
48
3.2
192max
300max
150max
200max
350max
400max
480max
600max
192max
28.5 - 31.5 46.0 - 50.0
*1
Peak load for 10 sec. or less is acceptable if the total wattage is less than the rated wattage.
*2
This is the value that measured on measuring board with capacitor of 22mF within 150mm
from output terminal.
Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN:
RM101).
*3
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C,
E-24