欢迎访问ic37.com |
会员登录 免费注册
发布采购

LEB100F-0530 参数 Datasheet PDF下载

LEB100F-0530图片预览
型号: LEB100F-0530
PDF下载: 下载PDF文件 查看货源
内容描述: 坚固型PCB [Rugged PCB type]
分类和应用: PC
文件页数/大小: 2 页 / 110 K
品牌: RSG [ RSG ELECTRONIC COMPONENTS GMBH ]
 浏览型号LEB100F-0530的Datasheet PDF文件第2页  
Rugged PCB type
Ordering information
LEB100F
R
LEB 100
1
2
3
F
4
-05
5
24
6
-O
Recommended Noise Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The
Noise Filter is recommended
*to
connect with several devices.
1Series
name
2Output
wattage
3Universal
input
4V1
Output voltage
5V2
Output voltage
6Optional
*1
G :Low leakage current
R :with Remote ON/OFF
S :with Chassis
SN :with Chassis & cover
T :Vertical terminal block
Y :with Potentiometer
Z :with ZT
MODEL
DC OUTPUT
V1
V2
LEB100F-0512
+5V 5A
+12V 5(Peak 10)A
LEB100F-0324
+3.3V 5A
+24V 4(Peak 7)A
LEB100F-0524
+5V 5A
+24V 4(Peak 7)A
LEB100F-0530
+5V 5A
+30V 3.2(Peak 5.6)A
LEB100F-0536
+5V 5A
+36V 2.7(Peak 4.7)A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
INPUT
ACIN 100V
ACIN 200V
ACIN 100V
POWER FACTOR
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
*
2
TOTAL OUTPUT WATTAGE[W]
*
3
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50
C
*
4
RIPPLE[mVp-p]
-10 - 0
C
*
4
0 to +50
C
*
4
RIPPLE NOISE[mVp-p]
-10 - 0
C
*
4
0 to +50
C
TEMPERATURE REGULATION[mV]
-10 to +50
C
DRIFT[mV]
*
5
START-UP TIME[ms]
*
6
HOLD-UP TIME[ms]
*
6
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
V1
OVERCURRENT PROTECTION
V2
V1
OVERVOLTAGE PROTECTION
V2
REMOTE ON/OFF
INPUT-OUTPUT
-
RC
*
7
INPUT-FG
OUTPUT
-
RC-FG
*
7
OUTPUT-OUTPUT(V1
-
RC-V2)
*
7
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
EFFICIENCY[%]
ACIN 100V
ACIN 200V
LEB100F-0512
LEB100F-0324
LEB100F-0524
LEB100F-0530
AC85 - 264 1
f
or DC 120 - 370
1.2typ (Io=100%)
1.4typ (Io=100%)
0.6typ (Io=100%)
0.7typ (Io=100%)
50/60 (47 - 63) or DC
74typ (Io=100%)
78typ (Io=100%)
78typ (Io=100%)
78typ (Io=100%)
76typ (Io=100%)
80typ (Io=100%)
80typ (Io=100%)
80typ (Io=100%)
0.98typ
0.99typ
0.93typ
15typ (Io=100%) (At cold start) (Ta=25
C
)
30typ (Io=100%) (At cold start) (Ta=25
C
)
0.75max (60Hz, According to IEC60950 and DEN-AN)
+5
+12
+3.3
+24
+5
+24
+5
+30
0-5
0 - 5 (Peak 10) 0 - 5
0 - 4 (Peak 7) 0 - 5
0 - 4 (Peak 7) 0 - 5
0 - 3.2 (Peak 5.6)
(Peak 145)
(Peak 172)
(Peak 172)
(Peak 172)
85
100
100
100
20max
48max
20max
96max
20max
96max
20max
120max
40max
100max
40max
150max
40max
150max
40max
180max
80max
120max
80max
120max
80max
120max
80max
200max
140max
160max
140max
160max
140max
160max
140max
240max
120max
150max
120max
150max
120max
150max
120max
300max
160max
180max
160max
180max
160max
180max
160max
360max
50max
120max
50max
240max
50max
240max
50max
300max
60max
150max
60max
290max
60max
290max
60max
350max
20max
48max
20max
96max
20max
96max
20max
120max
250max
500max
250max
500max
250max
500max
250max
500max
40typ
20typ
40typ
20typ
40typ
20typ
40typ
20typ
4.5 - 5.5
Fixed
2.85 - 3.60 Fixed
4.5 - 5.5
Fixed
4.5 - 5.5
Fixed
11.5 - 12.5
xx
23.0 - 25.0
xx
23.0 - 25.0
xx
28.7 - 31.5
xx
Works over 105% of rating current and recovers automatically
Works over 101% of peak current and recovers automatically
Works over 115% of rating, by zener diode clamping
Works at 115 - 140% of rating
Option (Refer to Instruction Manual)
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
AC100V 1minute, Cutoff current = 100mA, DC100V 10M
W
min (At Room Temperature)
-10 to +70
C
, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL, EN60950-1, EN50178 Complies with DEN-AN and IEC60950-1 (At only AC input)
Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
Complies with IEC61000-3-2
75
X
35
X
222mm (W
X
H
X
D) /420g max (without chassis and cover)
Convection
*6
*7
*
*
*
with the input voltage held constant at the rated input/output.
ACIN 100V,lo=100%
Applicable when remote control (optional) is added.
Series/Parallel operation is not possible.
Derating is required when operated with chassis and cover.
A sound may occur from power supply at peak loading.
LEB100F-0536
78typ (Io=100%)
80typ (Io=100%)
LEB
OUTPUT
+5
+36
0-5
0 - 2.7 (Peak 4.7)
(Peak 172)
100
20max
144max
40max
180max
80max
200max
140max
240max
120max
300max
160max
360max
50max
300max
60max
350max
20max
144max
250max
500max
40typ
20typ
4.5 - 5.5
Fixed
34.5 - 37.5
xx
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
*2
*3
*4
Specification is changed at option, refer to Instruction Manual 5.
Peak loading for 10sec. And Duty 35% max, refer to Instruction Manual 4. In detail.
Refer to Instruction Manual 2.2 in detail.
This is the value that measured on measuring board with capacitor of 22mF within 150mm
from output terminal.Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to
KEISOKU-GIKEN: RM101).
*5
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C,
F-2