欢迎访问ic37.com |
会员登录 免费注册
发布采购

LEP100F-24 参数 Datasheet PDF下载

LEP100F-24图片预览
型号: LEP100F-24
PDF下载: 下载PDF文件 查看货源
内容描述: 坚固型PCB [Rugged PCB type]
分类和应用: PC
文件页数/大小: 2 页 / 117 K
品牌: RSG [ RSG ELECTRONIC COMPONENTS GMBH ]
 浏览型号LEP100F-24的Datasheet PDF文件第2页  
Rugged PCB type
Ordering information
LEP100F
R
LEP 100
1
2
3
F
4
-24
5
-O
1Series
name
2Output
wattage
3Universal
input
4Output
voltage
5Optional
*
1
G :Low leakage current
R :with Remote ON/OFF
S :with Chassis
SN:with Chassis & cover
T :Vertical terminal block
U :Operating stop voltage
is set at a lower value
Z :with ZT
Recommended Noise Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The
Noise Filter is recommended
*to
connect with several devices.
MODEL
DC OUTPUT
LEP100F-24
+24V 4.2(Peak 7)A
LEP100F-36
+36V 2.8(Peak 4.7)A
LEP100F-48
+48V 2.1(Peak 3.5)A
SPECIFICATIONS
LEP
MODEL
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
INPUT
ACIN 100V
ACIN 200V
ACIN 100V
POWER FACTOR
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
*
2
WATTAGE[W]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50
C
*
3
RIPPLE[mVp-p]
-10 - 0
C
*
3
0 to +50
C
*
3
RIPPLE NOISE[mVp-p]
-10 - 0
C
*
3
0 to +50
C
TEMPERATURE REGULATION[mV]
-10 to +50
C
DRIFT[mV]
*
4
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
REMOTE ON/OFF
INPUT-OUTPUT
-
RC
*
5
INPUT-FG
OUTPUT
-
RC-FG
*
5
OUTPUT-RC
*
5
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CE MARKING
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
EFFICIENCY[%]
ACIN 100V
ACIN 200V
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
LEP100F-24
LEP100F-36
LEP100F-48
AC85 - 264 1
f
or DC 120 - 370
1.4typ (Io=100%)
0.7typ (Io=100%)
50/60 (47 - 63) or DC
81typ (Io=100%)
82typ (Io=100%)
83typ (Io=100%)
84typ (Io=100%)
85typ (Io=100%)
85typ (Io=100%)
0.98typ (Io=100%)
0.93typ (Io=100%)
15typ (Io=100%) (At cold start) (Ta=25
C
)
30typ (Io=100%) (At cold start) (Ta=25
C
)
0.75max (60Hz, According to IEC60950 and DEN-AN)
+24
+36
+48
0 - 4.2 (Peak 7)
0 - 2.8 (Peak 4.7)
0 - 2.1 (Peak 3.5)
100.8 (Peak 168)
100.8 (Peak 169.2)
100.8 (Peak 168)
48max
48max
48max
76max
90max
150max
120max
120max
150max
160max
160max
300max
150max
150max
250max
180max
180max
350max
120max
150max
240max
145max
180max
300max
48max
48max
48max
500max (ACIN 100V, Io=100%)
20typ (ACIN 100V, Io=100%)
21.4 - 26.4
26.4 - 39.6
39.6 - 52.8
23.0 - 25.0
35.0 - 37.0
46.0 - 50.0
Works over 101% of peak current and recovers automatically
Works at 115 - 140% of rating
Option (Refer to Instruction Manual)
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
AC100V 1minute, Cutoff current = 100mA, DC100V 10M
W
min (At Room Temperature)
-10 to +70
C
, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN and IEC60950-1 (At only AC input)
Low Voltage Directive, EMC Directive
Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
Complies with IEC61000-3-2
75
X
35
X
222mm (W
X
H
X
D) /380g max (without chassis and cover)
Convection
*5
*
*
*
Applicable when remote control (optional) is added.
Parallel operation with other model is not possible.
Derating is required when operated with chassis and cover.
A sound may occur from power supply at peak loading.
*1
Specification is changed at option, refer to Instruction Manual 6.
*2
Peak loading for 10sec. And Duty 35% max, refer to Instruction Manual 5. In detail.
*3
This is the value that measured on measuring board with capacitor of 22mF within 150mm
from output terminal.Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to
KEISOKU-GIKEN: RM101).
*4
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C,
with the input voltage held constant at the rated input/output.
E-4