型号: PAA150F-48
PDF下载: 下载PDF文件 查看货源
内容描述: 单位类型 [Unit type]
分类和应用:
文件页数/大小: 2 页 / 94 K
品牌: RSG [ RSG ELECTRONIC COMPONENTS GMBH ]
 浏览型号PAA150F-48的Datasheet PDF文件第2页  
Unit type
Ordering information
PAA
PAA150F
R
PAA 150
1
2
3
F
4
-5
5
-O
1Series
name
2Output
wattage
3Universal
input
4Output
voltage
5Optional
C :with Coating
G :Low leakage current
N :with Cover
R :with Remote ON/OFF
Recommended Noise Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The
Noise Filter is recommended
*to
connect with several devices.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
PAA150F-3
90
3V 30A
PAA150F-5
150
5V 30A
PAA150F-12
156
12V 13A
PAA150F-15
150
15V 10A
PAA150F-24
156
24V 6.5A
PAA150F-48
158.4
48V 3.3A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
EFFICIENCY[%]
PAA150F-3
PAA150F-5
AC85 - 264 1
f
or DC120 - 340
ACIN 100V
1.4typ
2.0typ
ACIN 200V
0.7typ
1.0typ
50/60 (47 - 63)
PAA150F-12
PAA150F-15
PAA150F-24
PAA150F-48
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
*2
*3
*
ACIN 100V
POWER FACTOR
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50
C
*
1
RIPPLE[mVp-p]
-10 - 0
C
*
1
0 to +50
C
*
1
RIPPLE NOISE[mVp-p]
-10 - 0
C
*
1
0 to +50
C
TEMPERATURE REGULATION[mV]
-10 to +50
C
*
2
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
*
3
INPUT-OUTPUT
-
RC
INPUT-FG
*
3
OUTPUT
-
RC-FG
*
3
OUTPUT-RC
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
67typ
75typ
78typ
80typ
81typ
0.99typ (Io=100%)
0.95typ (Io=100%)
20typ (Io=100%) (At cold start)
40typ (Io=100%) (At cold start)
0.75max (60Hz, According to UL, CSA, VDE and DEN-AN)
3
5
12
15
24
30
30
13
10
6.5
20max
20max
48max
60max
96max
40max
40max
100max
120max
150max
80max
80max
120max
120max
120max
140max
140max
160max
160max
160max
120max
120max
150max
150max
150max
160max
160max
180max
180max
180max
50max
50max
120max
150max
240max
60max
60max
150max
180max
290max
20max
20max
48max
60max
96max
500max (ACIN 85V, Io=100%)
20typ (Io=100%)
2.85 - 3.6
t
10%
Works over 105% of rating and recovers automatically
4.00 - 5.25V
Works at 115 - 140% of rating
(Green)
LED
Provided
Optional (Refer to Instruction Manual)
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
AC100V 1minute, Cutoff current = 100mA, DC100V 10M
W
min (At Room Temperature)
-10 to +65
C
, 10 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet)
-20 to +75
C
, 10 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, EN60950-1, EN50178, CSA C22.2 No.234 Complies with DEN-AN and IEC60950-1
Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
Complies with IEC61000-3-2
65
X
93
X
199mm (without terminal block) (W
X
H
X
D) /900g max (without cover)
Convection
81typ
48
3.3
192max
240max
150max
200max
400max
600max
480max
600max
192max
max
According to 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
Drift is change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
Applicable when Remote ON/OFF(optional) is added.
Derating is required when operated with cover.
A-54
Distribution:
RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany
Tel. +49 69 984047-0 Fax +49 69 984047-77 info@rsg-electronic.de
www.rsg-electronic.de
Änderungen vorbehalten / subject to change without notice