欢迎访问ic37.com |
会员登录 免费注册
发布采购

PBA15F-48 参数 Datasheet PDF下载

PBA15F-48图片预览
型号: PBA15F-48
PDF下载: 下载PDF文件 查看货源
内容描述: 单位类型 [Unit type]
分类和应用:
文件页数/大小: 2 页 / 129 K
品牌: RSG [ RSG ELECTRONIC COMPONENTS GMBH ]
 浏览型号PBA15F-48的Datasheet PDF文件第2页  
PB
Unit type
Ordering information
PBA15F
R
PB
1
2
A
3
15
4
F
5
-O
6
-O
Recommended Noise Filter
NAC-06-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The
Noise Filter is recommended
*to
connect with several devices.
1Series
name
2Single
output
3Output
wattage
4Universal
input
5Output
voltage
6Optional
C :with Coating
G :Low leakage current
E :Low leakage current
and EMI class A
T :Vertical terminal block
J :Connector type
N :with Cover
(UL508 is pending for approval)
N1 :with DIN rail
V :Output voltage setting
potentiometer external-
ly
Cover is optional
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
PBA15F-3R3
9.9
3.3V 3A
PBA15F-5
15
5V 3A
PBA15F-9
15.3
9V 1.7A
PBA15F-12
15.6
12V 1.3A
PBA15F-15
15
15V 1A
PBA15F-24
16.8
24V 0.7A
PBA15F-48
16.8
48V 0.35A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
INPUT
EFFICIENCY[%]
PBA15F-3R3
PBA15F-5
PBA15F-9
PBA15F-12
PBA15F-15
PBA15F-24
PBA15F-48
(AC50 or DC70 Please refer to the instruction manual 2.1 Input voltage
*
3)
AC85 - 264 1
f
or DC110 - 370
ACIN 100V
0.30typ (Io=100%) 0.4typ (Io=100%)
ACIN 200V
0.15typ (Io=100%) 0.2typ (Io=100%)
50/60 (47 - 440) or DC
68typ
74typ
75typ
75typ
77typ
75typ
75typ
68typ
75typ
77typ
78typ
80typ
78typ
78typ
15typ (Io=100%) (At cold start)
30typ (Io=100%) (At cold start)
0.15/0.30max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)
3.3
5
9
12
15
24
48
3
3
1.7
1.3
1
0.7
0.35
20max
20max
36max
48max
60max
96max
192max
40max
40max
100max
100max
120max
150max
240max
80max
80max
120max
120max
120max
120max
150max
140max
140max
160max
160max
160max
160max
200max
120max
120max
150max
150max
150max
150max
250max
160max
160max
180max
180max
180max
180max
300max
50max
50max
90max
120max
150max
240max
480max
60max
60max
120max
150max
180max
290max
600max
20max
20max
36max
48max
60max
96max
192max
(ACIN 100V, Io=100%)
*
Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.
200typ
20typ (ACIN 100V, Io=100%)
2.85 - 3.60
4.50 - 5.50
7.50 - 10.0
10.0 - 13.2
13.2 - 18.0
19.2 - 27.0
3.30 - 3.40
5.00 - 5.15
9.00 - 9.36
12.00 - 12.48
15.00 - 15.60
24.00 - 24.96
Works over 105% of rated current and recovers automatically
4.00 - 5.25
5.75 - 7.00
11.5 - 14.0
15.0 - 18.0
20.0 - 25.0
30.0 - 37.0
LED (Green)
None
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50M
W
min (At Room Temperature)
-10 to +71
C
(Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
-20 to +75
C
, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Low Voltage Directive, EMC Directive
Complies with IEC61000-3-2 (Not built-in to active filter
*
4)
31
X
78
X
85mm (without terminal block) (W
X
H
X
D) / 200g max (without cover)
Convection
*
*
*
Parallel operation with other model is not possible.
Derating is required when operated with cover.
A sound may occur from power supply at peak loading.
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
ACIN 100V
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50
C
*
1
RIPPLE[mVp-p]
-10 - 0
C
*
1
0 to +50
C
*
1
RIPPLE NOISE[mVp-p]
-10 - 0
C
*
1
0 to +50
C
TEMPERATURE REGULATION[mV]
-10 to +50
C
*
2
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION[V]
OPERATING INDICATION
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS (At only AC input)
CONDUCTED NOISE
CE MARKING
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
39.0 - 53.0
48.00 - 49.92
58.0 - 65.0
*1
Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101).
*2
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3
Derating is required.
*4
When two or more units are used,they may not comply with the harmonic attenuator. Please
Distribution:
contact us for details.
A-6
RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany
Tel. +49 69 984047-0 Fax +49 69 984047-77 info@rsg-electronic.de
www.rsg-electronic.de
Änderungen vorbehalten / subject to change without notice