欢迎访问ic37.com |
会员登录 免费注册
发布采购

PT-65A 参数 Datasheet PDF下载

PT-65A图片预览
型号: PT-65A
PDF下载: 下载PDF文件 查看货源
内容描述: 65W三路输出开关电源 [65W Triple Output Switching Power Supply]
分类和应用: 开关输出元件输入元件
文件页数/大小: 2 页 / 121 K
品牌: RSG [ RSG ELECTRONIC COMPONENTS GMBH ]
 浏览型号PT-65A的Datasheet PDF文件第2页  
ELECTRONIC COMPONENTS
RSG
RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany
Tel. +49 69 984047-0 Fax +49 69 984047-77 info@rsg-electronic.de
www.rsg-electronic.de
Änderungen vorbehalten / subject to change without notice
65W Triple Output Switching Power Supply
Features :
P T- 6 5
series
Universal AC input/Full range
Low leakage current<0.5mA
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 65KHz
2 years warranty
SPECIFICATION
MODEL
OUTPUT NUMBER
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT POWER (max.)
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
INPUT
EFFICIENCY(Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
ISOLATION RESISTANCE
EMC
EMI CONDUCTION & RADIATION
(Note 4)
HARMONIC CURRENT
EMS IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
NOTE
PT-65A
CH1
5V
5.5A
0.4 ~ 7A
60W
CH2
12V
2.5A
CH3
-5V
0.5A
PT-65B
CH1
5V
5.5A
0.4 ~ 7A
63.5W
CH2
12V
2.5A
CH3
-12V
0.5A
PT-65C
CH1
5V
5.5A
0.4 ~ 7A
65W
CH2
15V
2A
CH3
-15V
0.5A
PT-65D
CH1
5V
4A
0.5 ~ 5A
68W
CH2
12V
2A
0.2 ~ 4A
CH3
24V
1A
0.2 ~ 1.3A
0.2 ~ 3.2A 0 ~ 0.7A
0.2 ~ 3.2A 0 ~ 0.7A
0.2 ~ 2.6A 0 ~ 0.7A
Rated output power for convection; 72W with 18CFM min. Forced air
RIPPLE & NOISE (max.)
Note.2
50mVp-p 120mVp-p 50mVp-p 50mVp-p 120mVp-p 100mVp-p 50mVp-p 120mVp-p 100mVp-p 50mVp-p 100mVp-p 200mVp-p
CH1:4.75 ~ 5.5V
VOLTAGE TOLERANCE
Note.3
4.0%
7.0%
1.0%
3.0%
2.0%
4.0%
5.0%
1.0%
1.0%
4.0%
1.0%
3.0%
7.0%
2.0%
4.0%
5.0%
1.0%
1.0%
4.0%
1.0%
3.0%
7.0%
2.0%
4.0%
5.0%
1.0%
1.0%
4.0%
1.0%
2.0%
6.0%
2.0%
5.0%
6.0%
3.0%
5.0%
800ms, 20ms at full load
60ms at full load
90 ~ 264VAC
47 ~ 440Hz
76%
1.5A/115VAC
0.9A/230VAC
40A/230VAC
74.8 ~ 98.6W
rated output power
COLD START 20A/115VAC
<0.75mA
77%
77%
79%
127 ~370VDC
73 ~ 95W
rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
5.75 ~ 6.75VDC on CH1
Protection type : Hiccup mode, recovers automatically after fault condition is removed.
-10 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.04%/ (0 ~ 50 ) on +5V output
10 ~ 500Hz, 2G 10min./1cycle, Period for 60min.each along X, Y, Z axes
UL1950, TUV EN60950 Approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC 1min.
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
277.2K hrs min. MIL-HDBK-217F (25 )
127*76*42mm (L*W*H)
0.25Kg; 54pcs/15.9Kg/1.35CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Mounting holes M1 and M2 should be grounded for EMI purposes.
File Name:PT-65-SPEC 2006-12-19