欢迎访问ic37.com |
会员登录 免费注册
发布采购

QP-200D 参数 Datasheet PDF下载

QP-200D图片预览
型号: QP-200D
PDF下载: 下载PDF文件 查看货源
内容描述: 200W四路输出带PFC功能 [200W Quad Output with PFC Function]
分类和应用: 功率因数校正
文件页数/大小: 4 页 / 198 K
品牌: RSG [ RSG ELECTRONIC COMPONENTS GMBH ]
 浏览型号QP-200D的Datasheet PDF文件第2页浏览型号QP-200D的Datasheet PDF文件第3页浏览型号QP-200D的Datasheet PDF文件第4页  
ELECTRONIC COMPONENTS
RSG
RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany
Tel. +49 69 984047-0 Fax +49 69 984047-77 info@rsg-electronic.de
www.rsg-electronic.de
Änderungen vorbehalten / subject to change without notice
200W Quad Output with PFC Function
QP-200
series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections:Short circuit/Over load/Over voltage/Over temperature
Forced air cooling by built-in DC fan
CH1,2 can be adjustable from -5~+10%
With power good and fail signal output(Optional)
Built-in remote sense function for CH1,2
100% full load burn-in test
CH4 can set to positive after consult us before delivery
Fixed switching frequency at PFC:67KHz PWM:134KHz(Optional)
3 years warranty
..
SPECIFICATION
MODEL
OUTPUT NUMBER
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
PEAK CURRENT
OUTPUT
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
Note.3
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER LOAD
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
QP-200D
CH1
5V
15A
3 ~ 20A
203.4W
Note.4
20A
QP-200F
CH2
12V
4A
0 ~ 6A
7A
CH3
24V
3A
0.4 ~ 5A
6A
CH4
-12V
0.7A
0 ~ 1A
1A
CH1
5V
15A
3 ~ 20A
202.5W
20A
6A
6A
1A
CH2
15V
3A
0 ~ 5A
CH3
24V
3A
0.4 ~ 5A
CH4
-15V
0.7A
0 ~ 1A
QP-200-3A
CH1
5V
15A
3 ~ 20A
200W
20A
20A
8A
1A
CH2
3.3V
15A
0 ~ 20A
CH3
12V
6A
0.5 ~ 8A
CH4
-5V
0.7A
0 ~ 1A
RIPPLE & NOISE (max.)
Note.2
100mVp-p 150mVp-p 150mVp-p 150mVp-p 100mVp-p 150mVp-p 150mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p
CH1: 4.75 ~ 5.5V
3.0%
1.0%
2.0%
3.0%
1.0%
2.0%
CH2: 11.4 ~ 13.2V
+10,-6%
2.0%
6.0%
6.0%
1.0%
2.0%
CH1: 4.75 ~ 5.5V
3.0%
1.0%
2.0%
3.0%
1.0%
2.0%
CH2: 14.25 ~ 16.5V CH1: 4.75 ~ 5.5V
+10,-6%
2.0%
6.0%
6.0%
1.0%
2.0%
3.0%
1.0%
2.0%
3.0%
1.0%
2.0%
CH2: 3.14 ~ 3.63V
+8,-10%
2.0%
6.0%
6.0%
1.0%
2.0%
800ms, 50ms at full load
24ms at full load
Note.6
90 ~ 264VAC
127 ~ 370VDC
PF>0.98/115VAC at full load
75%
72%
47 ~ 63Hz
PF>0.95/230VAC
75%
3.5A/115VAC
2A/230VAC
COLD START 30A
<2mA / 240VAC
105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
CH1:5.75 ~ 6.75V
CH2:13.8 ~ 16.2V CH1: 5.75 ~ 6.75V
Protection type : Shut down o/p voltage, re-power on to recover
95
5
(TSW1) Detect on heatsink of Q1,Q2 power transistor
CH2:17.25 ~ 20.25V CH1:5.75 ~ 6.75V
CH2:3.8 ~ 4.4V
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION POWER GOOD / POWER FAIL(OPTIONAL)
10ms/1ms
-10 ~ +60 (Refer to output load derating curve)
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.03%/ (0~50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
I/P-O/P:3KVAC
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
SAFETY & ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
Compliance to EN55022 (CISPR22) Class B
EMC
(Note 5)
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
MTBF
OTHERS
NOTE
160.6K hrs min.
MIL-HDBK-217F (25
)
DIMENSION
PACKING
230*115*50mm (L*W*H)
1.2Kg; 12pcs/15.4Kg/0.92CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. 33.3% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
6. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:QP-200-SPEC 2005-09-13