ELECTRONIC COMPONENTS
RSG
RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany
Tel. +49 69 984047-0 Fax +49 69 984047-77 info@rsg-electronic.de
www.rsg-electronic.de
Änderungen vorbehalten / subject to change without notice
1000W Single Output Power Supply
Features :
RSP-1000
series
Universal AC input / Full range
AC input active surge current limiting
Built-in 5V/0.5A auxiliary power
Built-in active PFC function, PF>0.95
Protections:Short circuit/Over load/Over voltage/Over temperature
Output voltage can be trimmed between 40 ~ 110% of the rated output voltage
Forced air cooling by built-in DC fan
3
High power density 10.7w/inch
1U low profile 41mm
Active current sharing up to 4000W(3+1)
(Note.8)
DC OK Signal
Built-in remote ON-OFF control
Built-in remote sense function
3 years warranty
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
RSP-1000-12
12V
60A
0 ~ 60A
720W
RSP-1000-15
15V
50A
0 ~ 50A
750W
150mVp-p
13.5 ~ 16.5V
1.0%
0.5%
0.5%
16ms/115VAC at full load
127 ~ 370VDC
0.98/115VAC at full load
85%
6A/230VAC
40A/230VAC
88%
88%
RSP-1000-24
24V
40A
0 ~ 40A
960W
150mVp-p
20 ~ 26.4V
1.0%
0.5%
0.5%
RSP-1000-27
27V
37A
0 ~ 37A
999W
150mVp-p
24 ~ 30V
1.0%
0.5%
0.5%
..
RSP-1000-48
48V
21A
0 ~ 21A
1008W
150mVp-p
43 ~ 55V
1.0%
0.5%
0.5%
RIPPLE & NOISE (max.)
Note.2
150mVp-p
VOLTAGE ADJ. RANGE
10 ~ 13.5V
VOLTAGE TOLERANCE
Note.3
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
1.0%
0.5%
0.5%
300ms, 50ms at full load
16ms/230VAC
Note.5
90 ~ 264VAC
47 ~ 63Hz
0.95/230VAC
83%
12A/115VAC
25A/115VAC
<2.0mA / 240VAC
105 ~ 125% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
13.8 ~ 16.8V
17 ~ 20.5V
27.6 ~ 32.4V
31 ~ 36.5V
56.6 ~ 66.2V
Protection type : Shut down o/p voltage, re-power on to recover
5 (TSW1 ) Detect on heatsink of power transistor
85
5 (TSW2 ) Detect on heatsink of O/P diode; 75
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
5V @ 0.5A (+5%, -8%)
90%
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER LOAD
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
AUXILIARY POWER(AUX)
Power off : open between on/off(pin6) & -S(pin2) on CN50
REMOTE ON/OFF CONTROL
Note.6
Power on : short between on/off(pin6) & -S(pin2) on CN50
Open collector signal low when PSU turns on, Max. sink current :10mA
FUNCTION DC OK SIGNAL
OUTPUT VOLTAGE TRIM
Note.6
Adjustment of output voltage is possible between 40 ~ 110% of rated output
CURRENT SHARING(CS)
Note.7
Please refer to function manual
-20 ~ +60 (Refer to output load derating curve)
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
20 ~ 90% RH non-condensing
-40 ~ +85
, 10 ~ 95% RH
0.02%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
I/P-O/P:3KVAC
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
SAFETY & ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
Compliance to EN55022 (CISPR22)
EMC
(Note 4)
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
MTBF
OTHERS
NOTE
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61000-6-2, EN61204-3 Heavy industry level, criteria A
35K hrs min. MIL-HDBK-217F (25
295*127*41mm (L*W*H)
1.95Kg; 6pcs/12.7Kg/0.99CUFT
)
DIMENSION
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. The power supply unit will have no output if the shorting connector is not assembled. It contains two shorting wires: one is from on/off(pin6) to -s(pin2)
and the other is from Vco(pin8) to Vca(pin10). Please refter to function manual for details.
7. In parallel connection, maybe only one unit operate if the total output load is less than 5% of rated load condition.