欢迎访问ic37.com |
会员登录 免费注册
发布采购

RSP-1500-12 参数 Datasheet PDF下载

RSP-1500-12图片预览
型号: RSP-1500-12
PDF下载: 下载PDF文件 查看货源
内容描述: 1500W单路输出电源 [1500W Single Output Power Supply]
分类和应用:
文件页数/大小: 4 页 / 164 K
品牌: RSG [ RSG ELECTRONIC COMPONENTS GMBH ]
 浏览型号RSP-1500-12的Datasheet PDF文件第2页浏览型号RSP-1500-12的Datasheet PDF文件第3页浏览型号RSP-1500-12的Datasheet PDF文件第4页  
ELECTRONIC COMPONENTS
RSG
RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany
Tel. +49 69 984047-0 Fax +49 69 984047-77 info@rsg-electronic.de
www.rsg-electronic.de
Änderungen vorbehalten / subject to change without notice
1500W Single Output Power Supply
Features :
RSP-1500
series
Universal AC input/Full range
ZVS new technology
AC input active surge current limiting
High efficiency up to 91%
Built-in active PFC function,PF>0.95
Protections: Short circuit / Overload / Over voltage / Over temperature
Forced air cooling by built-in DC ball bearing fan
Output voltage can be trimmed between 70~100% of the rated output voltage
High power density 8.3W/inch
3
Current sharing up to 6000W(3+1)
Alarm signal output
Built-in 12V/0.1A auxiliary output for remote control
Built-in remote ON-OFF control
Built-in remote sense function
3 years warranty
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
RSP-1500-5
5V
240A
0 ~ 240A
1200W
RSP-1500-12
12V
125A
0 ~ 125A
1500W
150mVp-p
10 ~ 13.5V
1.0%
0.5%
0.5%
RSP-1500-15
15V
100A
0 ~ 100A
1500W
150mVp-p
13.5 ~ 16.5V
1.0%
0.5%
0.5%
14ms at full load
127 ~ 370VDC
0.98/115VAC at full load
87%
8A/230VAC
60A/230VAC
87%
90%
90%
91%
RSP-1500-24
24V
63A
0 ~ 63A
1512W
150mVp-p
20 ~ 26.4V
1.0%
0.5%
0.5%
RSP-1500-27
27V
56A
0 ~ 56A
1512W
150mVp-p
24 ~ 30V
1.0%
0.5%
0.5%
16ms at full load
RSP-1500-48
48V
32A
0 ~ 32A
1536W
200mVp-p
43 ~ 56V
1.0%
0.5%
0.5%
RIPPLE & NOISE (max.)
Note.2
150mVp-p
VOLTAGE ADJ. RANGE
4.5 ~ 5.5V
VOLTAGE TOLERANCE
Note.3
2.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
0.5%
2.0%
10ms at full load
90 ~ 264VAC
47~63Hz
0.95/230VAC
80%
17A/115VAC
30A/115VAC
<2.0mA / 240VAC
1500ms, 100ms at full load
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
Note.5
105 ~135% rated output power
Protection type : Constant current limiting unit will shut down o/p voltage after 5sec. Re-power on to recover
5.75 ~ 6.75V
13.8 ~ 16.8V
17 ~ 20.5V
27.6 ~ 32.4V
31 ~ 36.5V
57.6 ~ 67.2V
Protection type : Shut down o/p voltage, re-power on to recover
95
5 (TSW2 ) Detect on heatsink of power transistor
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
12V@0.1A(Only for Remote ON/OFF control)
Please see the Function Manual
Please see the Function Manual
Please see the Function Manual
Please see the Function Manual
-20 ~ +70
-40 ~ +85
(Refer to output load derating curve)
, 10 ~ 95% RH
20~90% RH non-condensing
0.05%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
AUXILIARY POWER(AUX)
REMOTE ON/OFF CONTROL
FUNCTION ALARM SIGNAL OUTPUT
OUTPUT VOLTAGE TRIM
CURRENT SHARING
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMC
EMI CONDUCTION & RADIATION
Compliance to EN55022 (CISPR22)
(Note 4)
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
MTBF
OTHERS
NOTE
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
62.6K hrs min. MIL-HDBK-217F (25
278*127*83.5mm (L*W*H)
2.6Kg; 6pcs/16.6Kg/1.54CUFT
)
DIMENSION
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:RSP-1500-SPEC 2007-03-19