欢迎访问ic37.com |
会员登录 免费注册
发布采购

SCP-2K4-48 参数 Datasheet PDF下载

SCP-2K4-48图片预览
型号: SCP-2K4-48
PDF下载: 下载PDF文件 查看货源
内容描述: 2400W并联型带PFC功能 [2400W Parallel Type With PFC Function]
分类和应用: 功率因数校正
文件页数/大小: 4 页 / 412 K
品牌: RSG [ RSG ELECTRONIC COMPONENTS GMBH ]
 浏览型号SCP-2K4-48的Datasheet PDF文件第2页浏览型号SCP-2K4-48的Datasheet PDF文件第3页浏览型号SCP-2K4-48的Datasheet PDF文件第4页  
ELECTRONIC COMPONENTS
RSG
RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany
Tel. +49 69 984047-0 Fax +49 69 984047-77 info@rsg-electronic.de
www.rsg-electronic.de
Änderungen vorbehalten / subject to change without notice
2400W Parallel Type With PFC Function
Features :
AC input 180~260VAC, 3
SCP-2K4
3 wire
series
AC 220V, 1 or 380V, 3 4 wire(option)
PF> 0.98@ 230VAC
Protections: Short circuit/ Overload/ Over voltage/ Over temperature
Built-in remote sense function, remote ON-OFF control
Power good signal
With parallel function(N+1)
Can adjust from 20~100% output voltage by external control 1-5V
Forced air cooling by built-in DC fan
Case coating with paint
3 years warranty
SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE, HOLD TIME
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR
INPUT
EFFICIENCY (Typ.)
AC CURRENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
OVER LOAD
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
Note. 4
SCP-2K4-09
2K4S-P009
9V
266A
0 ~ 266A
2400W
SCP-2K4-12
2K4S-P012
12V
200A
0 ~ 200A
2400W
120mVp-p
SCP-2K4-15
2K4S-P015
15V
160A
0 ~ 160A
2400W
150mVp-p
SCP-2K4-18
2K4S-P018
18V
133.3A
0 ~ 133.3A
2400W
150mVp-p
SCP-2K4-24
2K4S-P024
24V
100A
0 ~ 100A
2400W
150mVp-p
SCP-2K4-36
2K4S-P036
36V
66.6A
0 ~ 66.6A
2400W
200mVp-p
SCP-2K4-48
2K4S-P048
48V
50A
0 ~ 50A
2400W
200mVp-p
SCP-2K4-60
2K4S-P060
60V
40A
0 ~ 40A
2400W
200mVp-p
1.0%
0.5%
0.5%
RIPPLE & NOISE (max.)
Note.2
90mVp-p
3.0% Typical adjustment by potentiometer
VOLTAGE TOLERANCE
Note.3
2.0%
1.0%
1.0%
0.5%
1.5%
180 ~ 260VAC
47 ~ 63Hz
>0.98 / 230VAC
83%
15A / 230VAC
60A / 230VAC
3.5mA / 240VAC
110 ~ 140% rated output power
84%
85%
0.5%
0.5%
0.5%
0.5%
20% ~ 100% adjustment by 1 ~ 5VDC external control
1.0%
1.0%
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
800ms, 400ms, 12ms at full load
3 3 wire (other system available)
86%
88%
88%
89%
89%
Protection type : Current limiting, delay shut down o/p voltage, re-power on to recover
110 ~ 135% Follow to output set up point
Protection type : Shut down o/p voltage, re-power on to recover
>100 / measure by heat sink, near transformer
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-20 ~ +65 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
0.04% / (0 ~ 50 )
10 ~ 200Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950, TUV EN60950-1 Approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE
I/P-O/P, I/P-FG, OP/FG:100M Ohms / 500VDC
EMI CONDUCTION & RADIATION
Compliance to EN55022 (CISPR22) class A
EMC
(Note. 5)
Compliance to EN61000-3-2,3
HARMONIC CURRENT
EMS IMMUNITY
POWER GOOD SIGNAL
SPECIAL FUNCTION
OTHERS
COOLING
MTBF
DIMENSION
PACKING
NOTE
Compliance to EN61000-4-2,3,4,5,6,8,11, Light industry level, criteria A
Open collector of NPN transistor
DC Voltage Adj., Remote sensing, remote control, parallel operation(refer to control terminal instruction manual)
By fan, >20% load or >50 fan on
24.9K hrs min. MIL-HDBK-217F(25
350*212*124mm (L*W*H)
9.0kg ; 1pcs / 10kg / CARTON
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Current limiting 3 times(1.5s,3.0s,5.0s)Then intelligent auto recovery before shut down
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:SCP-2K4-SPEC 2006-03-28