225W Single Output with PFC Function
Features :
USP-225
series
Universal AC input / Full range
Built in active PFC circuit compliance to EN61000-3-2
Protections:Short circuit/Over load/Over voltage/Over temperature
Free air convection for 150W and forced air convection for 225W
3
High power density 4.7w/in
Active AC surge current limiting
U-bracket low profile:38mm
3 years warranty
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
INPUT
EFFICIENCY (Typ.)
230VAC
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER LOAD
PROTECTION OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
EMC
(Note 4)
USP-225-3.3
3.3V
40A
0 ~ 40A
132W
USP-225-5
5V
40A
0 ~ 40A
200W
100mVp-p
4.5 ~ 5.5V
2.0%
0.5%
1.0%
USP-225-12
12V
18.7A
0 ~ 18.7A
224.4W
100mVp-p
10.8 ~ 13.2V
2.0%
0.5%
1.0%
USP-225-15
15V
15A
0 ~ 15A
225W
100mVp-p
13.5 ~ 16.5V
2.0%
0.5%
1.0%
USP-225-24
24V
9.4A
0 ~ 9.4A
225.6W
150mVp-p
21.6 ~ 26.4V
2.0%
0.5%
1.0%
USP-225-48
48V
4.7A
0 ~ 4.7A
225.6W
250mVp-p
43.2 ~ 52.8V
2.0%
0.5%
1.0%
RIPPLE & NOISE (max.)
Note.2
100mVp-p
2.97 ~ 3.6V
VOLTAGE TOLERANCE
Note.3
2.0%
0.5%
1.0%
500ms, 30ms/230VAC
22ms/230VAC
90 ~ 264VAC
47 ~ 63Hz
PF>0.93/230VAC
72%
115VAC
2.2A
1.1A
15A/115VAC
<3.5mA / 240VAC
1200ms, 30ms/115VAC at full load
22ms/115VAC at full load
127 ~ 370VDC
PF>0.97/115VAC at full load
77%
3.3A
1.6A
30A/230VAC
83%
84%
86%
86%
AC CURRENT
(Typ.)
105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
3.6 ~ 4.4V
5.5 ~ 7.4V
13.2 ~ 16.3V
Protection type : Shut down o/p voltage, re-power on to recover
95
5 (RTH2 : Detect on heatsink of power transistor)
-20 ~ +65
-40 ~ +85
(Refer to output load derating curve)
, 10 ~ 95% RH
16.5 ~ 20.2V
26.4 ~ 32.4V
52.8 ~ 64.8V
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
20 ~ 90% RH non-condensing
0.03%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 Approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION
Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, Light industry level, criteria A
220K hrs min. MIL-HDBK-217F (25 )
202*101.5*38mm (L*W*H)
0.85Kg; 16pcs/14.6Kg/0.76CUFT
ISOLATION RESISTANCE
OTHERS
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:USP-225-SPEC 2006-11-27