Transient Voltage Suppressors - 1.5KE Series
Electriacl Characteristics
Type Number
(UNI)
1.5KE6.8A
1.5KE7.5A
1.5KE8.2A
1.5KE9.1A
1.5KE10A
1.5KE11A
1.5KE12A
1.5KE13A
1.5KE15A
1.5KE16A
1.5KE18A
1.5KE20A
1.5KE22A
1.5KE24A
1.5KE27A
1.5KE30A
1.5KE33A
1.5KE36A
1.5KE39A
1.5KE43A
1.5KE47A
1.5KE51A
1.5KE56A
1.5KE62A
1.5KE68A
1.5KE75A
1.5KE82A
1.5KE91A
1.5KE100A
1.5KE110A
1.5KE120A
1.5KE130A
1.5KE150A
1.5KE160A
1.5KE170A
1.5KE180A
1.5KE200A
1.5KE220A
1.5KE250A
1.5KE300A
1.5KE350A
1.5KE400A
1.5KE440A
1.5KE480A
(BI)
1.5KE6.8CA
1.5KE7.5CA
1.5KE8.2CA
1.5KE9.1CA
1.5KE10CA
1.5KE11CA
1.5KE12CA
1.5KE13CA
1.5KE15CA
1.5KE16CA
1.5KE18CA
1.5KE20CA
1.5KE22CA
1.5KE24CA
1.5KE27CA
1.5KE30CA
1.5KE33CA
1.5KE36CA
1.5KE39CA
1.5KE43CA
1.5KE47CA
1.5KE51CA
1.5KE56CA
1.5KE62CA
1.5KE68CA
1.5KE75CA
1.5KE82CA
1.5KE91CA
1.5KE100CA
1.5KE110CA
1.5KE120CA
1.5KE130CA
1.5KE150CA
1.5KE160CA
1.5KE170CA
1.5KE180CA
1.5KE200CA
1.5KE220CA
1.5KE250CA
1.5KE300CA
1.5KE350CA
1.5KE400CA
1.5KE440CA
1.5KE480CA
Reverse Stand-
Off Voltage
VRWM
(V)
5.80
6.40
7.02
7.78
8.55
9.40
10.20
11.10
12.80
13.60
15.30
17.10
18.80
20.50
23.10
25.60
28.20
30.80
33.30
36.80
40.20
43.60
47.80
53.00
58.10
64.10
70.10
77.80
85.50
94.00
102.00
111.00
128.00
136.00
145.00
154.00
171.00
185.00
214.00
256.00
300.00
342.00
376.00
408.00
Breakdown
Voltage Min.@IT
V
BR MIN.(V)
6.45
7.13
7.79
8.65
9.50
10.50
11.40
12.40
14.30
15.20
17.10
19.00
20.90
22.80
25.70
28.50
31.40
34.20
37.10
40.90
44.70
48.50
53.20
58.90
64.60
71.30
77.90
86.50
95.00
105.00
114.00
124.00
143.00
152.00
162.00
171.00
190.00
209.00
237.00
285.00
332.00
380.00
418.00
456.00
V
BR.MAX.(V)
7.14
7.88
8.61
9.50
10.50
11.60
12.60
13.70
15.80
16.80
18.90
21.00
23.10
25.20
28.40
31.50
34.70
37.80
41.00
45.20
49.40
53.60
58.80
65.10
71.40
78.80
86.10
95.50
105.00
116.00
126.00
137.00
158.00
168.00
179.00
189.00
210.00
231.00
263.00
315.00
368.00
420.00
462.00
504.00
Test
Current
I
T(mA)
10
10
10
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Maximum
Clamping
Voltage@I
PP
V
C(V)
10.5
11.3
12.1
13.4
14.5
15.6
16.7
18.2
21.2
22.5
25.2
27.7
30.6
33.2
37.5
41.4
45.7
49.9
53.9
59.3
64.8
70.1
77.0
85.0
92.0
103.0
113.0
125.0
137.0
152.0
165.0
179.0
207.0
219.0
234.0
246.0
274.0
328.0
344.0
414.0
482.0
548.0
602.0
658.0
Peak Pulse
Current
IPP
(A)
144.8
134.5
125.6
113.4
104.8
97.4
91.0
83.5
71.7
67.6
60.3
54.9
49.7
45.8
40.5
36.7
33.3
30.5
28.2
25.6
23.5
21.7
19.7
17.9
16.5
14.8
13.5
12.2
11.1
10.0
9.20
8.50
7.30
6.60
6.50
6.20
5.50
4.60
4.40
3.70
3.20
2.80
2.50
2.30
Reverse
Leakage
@VRWM
IR
(µA)
1000
500
200
50
10
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
For bidirectional type having VR of 10 volts and less, the IR limit is double.
For parts without A, the VBR is +10% and VC is 5% higher than with A parts.
Circuit Protection
System
Specifications are subject to change without notice.
Please refer to
http://www.ruilon.com
for current information.
Page:2