LS 14500
Cell voltage (V)
Voltage plateau versus Current and Temperature (at mid-discharge)
3.8
3.6
3.4
3.2
3.0
2.8
2.6
2.4
2.2
0.1
1
+ 70ºC
+ 55ºC
+ 20ºC
Ø 4.2 min
5.5 max
(flat area)
- 20ºC
- 40ºC
10
100
1000
1.35 ± 0.3
Current (mA)
50 ± 0.3
Ø 14.44 ±
0.11
Typical discharge profiles at + 20°C
3.8
3.6
Cell voltage (V)
0.4 ± 0.1
3.4
3.2
400 Ohms/8.6 mA
3600 Ohms/1 mA
10000
57 Ohms/55 mA
3.0
2.8
2.6
2.4
2.2
2.0
0.1
1
Ø 7.5 ± 0.1
Dimensions in mm.
10
100
1000
Time (hours)
Storage
l
Restored Capacity versus Current and Temperature (2.0 V cut-off)
3.0
2.8
2.6
2.4
2.2
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0.0
0.01
0.1
1
10
100
1000
Warning
l
l
l
Fire, explosion and burn hazard.
Do not recharge, short circuit,
crush, disassemble, heat above
100°C
(212°F),
incinerate,
or expose contents to water.
Do not solder directly to the cell
(use tabbed cell versions instead).
Capacity (Ah)
The storage area should be
clean, cool
(preferably not
exceeding + 30°C),
dry and
ventilated.
Current (mA)
Doc. N
o
31064-2-0909
Saft
Specialty Battery Group
12, rue Sadi Carnot
93170 Bagnolet - France
Tel.: +33 (0)1 49 93 19 18
Fax : +33 (0)1 49 93 19 69
www.saftbatteries.com
Information in this document is subject to change without notice
and becomes contractual only after written confirmation by Saft.
For more details on primary lithium technologies please refer to
Primary Lithium Batteries Selector Guide Doc N
o
31048-2.
Published by the Communications Department.
Photo credit: Saft
Société anonyme au capital de 31 944 000
RCS Bobigny B 383 703 873
Produced by Arthur Associates Limited.
1000 Ohms/3.6 mA