欢迎访问ic37.com |
会员登录 免费注册
发布采购

SA2002PSA 参数 Datasheet PDF下载

SA2002PSA图片预览
型号: SA2002PSA
PDF下载: 下载PDF文件 查看货源
内容描述: 可编程单相千瓦小时的能量集成电路的机械计数器应用 [Programmable Single Phase Kilowatt-hour Energy IC for Mechanical Counter Application]
分类和应用: 计数器机械
文件页数/大小: 14 页 / 127 K
品牌: SAMES [ SAMES ]
 浏览型号SA2002PSA的Datasheet PDF文件第1页浏览型号SA2002PSA的Datasheet PDF文件第3页浏览型号SA2002PSA的Datasheet PDF文件第4页浏览型号SA2002PSA的Datasheet PDF文件第5页浏览型号SA2002PSA的Datasheet PDF文件第6页浏览型号SA2002PSA的Datasheet PDF文件第7页浏览型号SA2002PSA的Datasheet PDF文件第8页浏览型号SA2002PSA的Datasheet PDF文件第9页  
SA2002P
sames
#
ELECTRICAL CHARACTERISTICS
(V
DD
= 2.5V, V
SS
= -2.5V, over the temperature range -10°C to +70°C , unless otherwise specified.)
Parameter
Operating temp. Range
Supply Voltage: Positive
Supply Voltage: Negative
Supply Current: Positive
Supply Current: Negative
Current Sensor Inputs (Differential)
Input Current Range
Symbol
Min
-25
2.25
-2.75
Typ
Max
+85
2.75
-2.25
Unit
°C
V
V
mA
mA
Condition
T
O
V
DD
V
SS
I
DD
I
SS
5
5
6
6
I
I I
-25
+25
µA
Peak value
Voltage Sensor Input (Asymmetrical)
Input Current Range
Pin VREF
Ref. Current
Ref. Voltage
Digital I/O
Pins RLOAD, TEST, SDA
Input High Voltage
Input Low Voltage
Pins MOP, MON, LED, FMO,
SCL, DIRO
Output High Voltage
Output Low Voltage
Pin SDA
Pull up current
Pin RLOAD, TEST
Pull down current
V
I H
V
I L
V
OH
V
OL
V
DD
-1
V
SS
+1
V
DD
-1
V
SS
+1
V
V
V
V
I
OH
= -2mA
I
OL
= 5mA
I
I V
-I
R
V
R
-25
45
1.1
50
+25
55
1.3
µA
µA
V
Peak value
With R = 24k
W
connected to V
SS
Reference to V
SS
-I
I L
I
I H
24
48
54
110
µA
µA
V
I
= V
SS
V
I
= V
DD
#Extended Operating Temperature Range available on request.
ABSOLUTE MAXIMUM RATINGS*
Parameter
Supply Voltage
Current on any pin
Storage Temperature
Operating Temperature
Symbol
Min
3.6V
-150
-40
-40
Max
6.0
+150
+125
+85
Unit
V
mA
°C
°C
V
DD
-V
SS
I
PI N
T
STG
T
O
*Stresses above those listed under “Absolute Maximum Ratings” may
cause permanent damage to the device. This is a stress rating only.
Functional operation of the device at these or any other condition above
those indicated in the operational sections of this specification, is not
implied. Exposure to Absolute Maximum Ratings for extended periods
may affect device reliability.
ATTENTION!
Electrostatic
sensitive devices.
Requires special
handling.
2/14