0071.2561.A2 参数 Datasheet PDF下载

0071.2561.A2图片预览
型号: 0071.2561.A2
PDF下载: 下载PDF文件 查看货源
内容描述: 120 - 360 VAC · 800 - 13000 A· 5 - 25毫米 [120 - 360 VAC · 800 - 13000 A · 5 - 25 mm]
分类和应用:
文件页数/大小: 8 页 / 1057 K
品牌: SCHURTER [ SCHURTER INC. ]
 浏览型号0071.2561.A2的Datasheet PDF文件第2页浏览型号0071.2561.A2的Datasheet PDF文件第3页浏览型号0071.2561.A2的Datasheet PDF文件第4页浏览型号0071.2561.A2的Datasheet PDF文件第5页浏览型号0071.2561.A2的Datasheet PDF文件第6页浏览型号0071.2561.A2的Datasheet PDF文件第7页浏览型号0071.2561.A2的Datasheet PDF文件第8页  
Varistors
www.schurter.com/pg03
Last order date: 31.10.2012
AVTP
Disc Size: 7 mm
Disc Size: 14 mm
120 - 360 VAC · 800 - 13000 A · 5 - 25 mm
Description
- Radial Leaded Varistor
- Low leackage current
- VDE, UL, CSA approvals
Standards
- IEC 61051 - Varistors for Use in Electronic Equipment
- UL 1414 - Across-the-Line Components
- UL 1449 - Transient Voltage Surge Suppressors
- CSA C22.2 - Accessories and Parts for Electronic Equipment
Approvals
- VDE Certificate Number: 40026011
- UL File Number: E340137 (UL 1449), E325083 (UL 1414)
- CSA File Number: 2088244
PH
A
Dimensions
A
max
E
max
B
max
D
C
25
F
Rated Voltage
120 - 360 VAC, 160 - 470 VDC
Disc Size
5 - 25 mm
Peak Current 8/20 µs, 1 Pulse 800 - 13000 A
Max. Energy Absorption
8 - 440 J
10/1000 µs
Current/Energy Derating above - 2.5% / °C
85 °C
Voltage/Temperature Coeffi-
- 0.05% / °C
cient
Mounting
PCB,THT
Admissible Ambient Air Temp. - 40 °C to 85 °C
Material: Terminals
Tin-Plated Copper Alloy
Material: Tube
Zinc Oxide
Storage Conditions
0 °C to 60 °C max. 70% r.h.
Product Marking
, Order Number, Approvals, Data
Code
SE
Drilling diagram
Technical Data
-O
UT
Disc Size: 25 mm
Applications
- Surge protection
- Primary Protection Single-Phase
- Surge Protection according to IEC 61000-4-5
References
Weblinks
Packaging Details
pdf, html, General Product Information, Approvals, RoHS, CHINA-RoHS,
e-Shop, SCHURTER-Stock-Check, Distributor-Stock-Check
Soldering Methods
Solderability
Resistance to Soldering Heat
Insulation Resistance
HiPot Encapsulation
Impulse Response Time
DC Leackage Current
Flammability
Wave
235 °C / 2 sec acc. to IEC 60068-2-20
Test Ta, method 1
260 °C / 5 sec acc. to IEC 60068-2-20,
Test Tb, method 1A
>10'000 MΩ
2500 VDC
< 50 ns
< 200 µA
UL 94V-0
D +0.5
G
Fuses