Power entry modules without line filter
IEC Appliance Inlet C14 with Fuseholder 1- or 2-pole
092
C14
70° C
- Panel Mount:
- Screw-on from front side,
- Appliance Inlet,
- Protection class I Fuseholder for fuse-links 5 x 20 mm 2-pole, Protec-
tion class I, Pin temperature 70 °C
- Solder terminals or quick connect terminals
Description
Characteristics
- The fuseholder is accessible from the equipment front
The fuse drawer "Fingergrip" can be removed by hand
- With or without rear-side insulation cover
References
Weblinks
Approvals
- CSA License Number: 1084381
Technical Data
Ratings IEC
Ratings UL/CSA
Dielectric Strength
10 A / 250 VAC; 50 Hz
10 A / 250 VAC; 60 Hz
> 3 kVAC between L-N
> 1.5 kVAC between L/N-PE
(1 min/50 Hz)
-25 °C to 70 °C
from front side IP 20 acc. to IEC 60529
Suitable for appliances with protection
class 1 acc. to IEC 61140
Solder terminals or quick connect termi-
nals Solder terminals or quick connect
terminals straight
UL 94V-0
Appliance Inlet
C14 acc. to IEC/EN 60320-1
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class 1
2-pole, acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
Admissible power acceptance at hig-
her ambient temperature see derating
curves
Fuseholder
Power Acceptance @ Ta >
23°C
Allowable Operation Temp.
Degree of Protection
Protection Class
Terminal
Material: Housing
Dimensions
44 mm
44
16.50
3.20
26.90
30.70
30.90
33
ø
20
3.
R
50
3.
28
36
lenght of the terminal please find at the order code configuration table
19.70
37.60
5.10
Connectors