欢迎访问ic37.com |
会员登录 免费注册
发布采购

5200 参数 Datasheet PDF下载

5200图片预览
型号: 5200
PDF下载: 下载PDF文件 查看货源
内容描述: IEC设备入口C14与过滤器,保险丝座1极 [IEC Appliance Inlet C14 with Filter, Fuseholder 1-pole]
分类和应用: 过滤器
文件页数/大小: 5 页 / 761 K
品牌: SCHURTER [ SCHURTER INC. ]
 浏览型号5200的Datasheet PDF文件第2页浏览型号5200的Datasheet PDF文件第3页浏览型号5200的Datasheet PDF文件第4页浏览型号5200的Datasheet PDF文件第5页  
Power Entry Modules with Line Filter
IEC Appliance Inlet C14 with Filter, Fuseholder 1-pole
5200
Plug removal necessary for fuse
replacement
Type 5200, Fuseholder 1-pole with spare com-
partment
Snap-In Version or Screw-On Version
Type 5200, Fuseholder 1-pole with spare com-
partment
Snap-In Version or Screw-On Version
C14
70° C
Description
- Panel Mount:
Snap-in or screw-on mounting from front side
- 3 Functions:
Appliance Inlet Protection class I, Fuseholder for fuse-links 5 x 20 mm
1-pole, Line filter in standard and medical version
- Quick connect terminals 6.3 x 0.8 mm
- Alternative: version without line filter 6200
Characteristics
- All single elements are already wired
- Plug removal necessary for fuse-link replacement
Fuse drawer meets requirements of medical standard IEC/EN 60601-1
The fuseholder is accessible from the equipment front
- Qualified for use in equipment according IEC/EN 60950
References
Weblinks
Approvals
- VDE License Number: 101307
- UL License Number: E72928
- CSA License Number: 97784
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 10 A @ Ta 40 °C / 125 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class 1 acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in: 0.8 mm to 3 mm
Thermoplastic, black, UL 94V-0
Appliance-Inlet/-Outlet
C14 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class 1
1-pole, Shocksafe category PC2 acc. to
IEC 60127-6,
for fuse-links 5 x 20 mm
5 x 20: 2 W (1 pole)
Admissible power acceptance at hig-
her ambient temperature see derating
curves
Standard and Medical Version, IEC
60939, IEC 60601-1, UL 1283, UL 544,
EN 133 200, CSA C22.2 no. 8
> 2'300'000 h acc. to MIL-HB-217 F
Fuseholder
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Line Filter
Material: Housing
MTBF
EMC Products