SC210KSIT
120 kHz Bandwidth, High Voltage Isolation
Current Sensor with Integrated Overcurrent Detection
Absolute Maximum Ratings
Characteristic
Supply Voltage
Filter Pin
Analog Output Pin
Overcurrent Input Pin
Overcurrent
FAULT
Pin
Fault Enable (FAULT_EN) Pin
Voltage Reference Output Pin
DC Reverse Voltage: V
CC,
FILTER, V
IOUT
,
V
OC
, FAUL,
FAULT
_EN, and V
ZCR
Pins
Excess to Supply Voltage: FILTER, V
IOUT
,
V
OC
,
FAULT
, FAULT_EN, and V
ZCR
Pins
Output Current Source
Output Current Sink
Operating Ambient Temperature
Junction Temperature
Storage Temperature
Symbol
V
CC
V
FILTER
V
IOUT
V
OC
V
FAULT
V
FAULTEN
V
ZCR
V
Rdcx
Voltage by which pin
voltage can exceed
the V
CC
pin voltage
Notes
Rating
8
8
32
8
8
8
8
–0.5
Unit
V
V
V
V
V
V
V
V
V
EX
I
IOUT(Source)
I
IOUT(Sink)
T
A
T
J(max)
T
stg
0.3
3
1
V
mA
mA
°C
°C
°C
Range K
–40 to 125
165
–65 to 170
Isolation Characteristics
Characteristic
Dielectric Strength Test Voltage*
Symbol
V
ISO
Notes
Agency type-tested for 60 seconds per
UL standard 1577
For basic (single) isolation per UL
standard 1577; for higher continuous
voltage ratings, please contact SEC
Rating
3000
Unit
VAC
Working Voltage for Basic Isolation
V
WFSI
277
VAC
Thermal Characteristics
Characteristic
Package Thermal Resistance
Symbol
R
θJA
Test Conditions
Value Unit
When mounted on SEC demo board with 1332 mm2 (654
mm2 on component side and 678 mm2 on opposite side)
17 ºC/W
of 2 oz. copper connected to the primary lead frame and
3/13