SIOLSV2
Current Sensors
Parameters Table
PARAMETERS
Supply voltage(±5%)
(1)
Current consumption
Output voltage
Isolation resistance
Output internal resistance
Load resistance
(2)
Linearity
(3)
(0…±I
PN
)
Accuracy
Electrical offset voltage
Hysteresis offset voltage
Temperature coefficient of V
OE
Temperature coefficient of
V
OUT
Response time
Frequency bandwidth
(4)
Ambient operating temperature
Ambient storage temperature
Mass
Rated isolation voltage rms
Rms voltage for AC
isolation test
SYMBOL
V
C
I
C
V
out
UNIT
Electrical data
V
mA
V
VALUE
±15
±15
±4
@ ± I
PN
, R
L
= 10 kΩ,
T
A
= 25°C
@ 500 VDC
CONDITIONS
R
IS
MΩ
>1000
R
OUT
Ω
100
R
L
KΩ
>10
Accuracy - Dynamic performance data
ε
L
X
G
V
OE
V
OH
TCV
OE
TCV
OUT
t
r
BW
% of I
PN
% of I
PN
mV
mV
mV/K
%/K
μS
kHz
<±1
<±1
<±20
<±10
<±1
<±0.1
<5
DC~25
@ I
PN
, T
A
= 25°C
@ I
PN
, T
A
= 25°C
(excluding offset)
@T
A
= 25°C
@ I
P
= 0
@ 90% of I
PN
@-3dB
General data
T
A
°C
-40 ~ +85
T
S
°C
-40 ~ +105
m
g
300
Isolation characteristics
Vb
V
1000
Vd
kV
3
@50 Hz, 1 min
Notes:
1) Operating at
±12V ≤VC<±15V
will reduce the measuring range.
2) If the customer uses 10KΩ of the load resistor, the primary current has to be limited as the
nominal.
3) Linearity data exclude the electrical offset.
4) Please refer to derating curves in the technical file to avoid excessive core heating at high
frequency.
2