SS129
Unipolar Hall-Effect Digital Switch
Glossary of Terms
MilliTesla (mT), Gauss
RoHS
Operating Point (B
OP
)
Release Point (B
RP
)
Units of magnetic flux density: 1mT = 10 Gauss
Restriction of Hazardous Substances
Magnetic flux density applied on the branded side of the package which turns the output
driver ON (V
OUT
= V
DSon
)
Magnetic flux density applied on the branded side of the package which turns the output
driver OFF (V
OUT
= high)
Pin Definitions and Descriptions
SOT Pin
№
SIP Pin
№
1
2
3
1
3
2
Name
VDD
OUT
GND
Type
Supply
Output
Ground
Function
Supply Voltage pin
Open Drain Output pin
Ground pin
Table 1: Pin definitions and descriptions
Absolute Maximum Ratings
Parameter
Symbol
Supply Voltage
V
DD
Supply Current
I
DD
Output Voltage
V
OUT
Output Current
I
OUT
Storage Temperature Range
T
S
Table 2: Absolute maximum ratings
Operating Temperature Range
Temperature Suffix “E”
Temperature Suffix “K”
Temperature Suffix “L”
Symbol
T
A
T
A
T
A
Value
28
50
28
50
-65 to 170
Units
V
mA
V
mA
°C
Value
-40 to 85
-40 to125
-40 to 150
Units
°C
°C
°C
Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute-maximum-rated
conditions for extended periods may affect device reliability.
2
V2.10
May 1, 2012