BUS13A
ELECTRICAL CHARACTERISTICS
(Tcase = 25°C unless otherwise stated)
Parameter
Test Conditions
Min.
V
CEOsust
I
CES
I
EBO
V
CE(sat)
V
BE(sat)
Collector Emitter Sustaining
Voltage
Collector Cut–Off Current
Emitter Cut–Off Current
Collector – Emitter Saturation
Voltage
Base – Emitter Saturation Voltage
I
C
= 100mA
L =25mH
V
CE
= V
CESMmax;
V
BE
=0
T
C
=125
°
C
V
EB
= 9V
I
C
= 8A
I
C
= 8A
I
C
= 0
I
B
= 1.6A
I
B
= 1.6A
I
Boff
= 0
450
Typ.
Max.
Unit
V
1
4
10
1.5
1.6
mA
mA
V
V
SWITCHING CHARACTERISTICS
(Tcase = 25°C unless otherwise stated)
t
on
t
s
t
f
On Time
Storage Time
Fall Time
I
C
= 8A
I
Bon
= -I
Boff
= 1.6A
1
4
0.8
µS
Semelab Plc reserves the right to change test conditions, parameter limits and package dimensions without notice. Information furnished by Semelab is believed
to be both accurate and reliable at the time of going to press. However Semelab assumes no responsibility for any errors or omissions discovered in its use.
Semelab encourages customers to verify that datasheets are current before placing orders.
Semelab plc.
Telephone +44(0)1455) 556565. Fax +44(0)1455) 552612.
E-mail:
sales@semelab.co.uk
Website:
http://www.semelab.co.uk
Document Number 5380
Issue 1