DC Series
SURSENSE
TM
precision very low pressure sensors /
V-output
PERFORMANCE CHARACTERISTICS
0.25...4.25 V ratiometric
output version
(
V
S
= 5.0 V, T
A
= 25°C, pressure applied to port 2)
Characteristics
Zero pressure offset
Full scale span
3
Total accuracy (0 - 50 °C)
4
DC...G...
DC...D...
DC...G...
DC...D...
DC001N...
DC2R5B...
DC002N..., DC2R5N...
DC005B...
all others
DC001N... to DC2R5N...
DC2R5B..., DC005B...
DC005N...
DC010B...
all others
DC...C4
Min.
Typ.
0.25
2.25
4.0
±2.0
±2.0
±1.5
±1.0
Max.
Unit
V
±3.0
±2.5
±2.0
±10
±5
±1
mV
%FSO
Offset position sensitivity (±1 g)
PERFORMANCE CHARACTERISTICS
0.25...4.25 V regulated
output version
(
V
S
= 15.0 V, T
A
= 25°C, pressure applied to port 2)
Characteristics
Zero pressure offset
Full scale span
3
Total accuracy (0 - 50 °C)
4
DC...G...
DC...D...
DC...G...
DC...D...
DC001N...
DC2R5B...
DC002N..., DC2R5N...
DC005B...
all others
DC001N... to DC2R5N...
DC2R5B..., DC005B...
DC005N...
DC010B...
all others
DC...R4
Min.
Typ.
0.25
2.25
4.0
±2.0
±2.0
±1.5
±1.0
Max.
Unit
V
±3.0
±2.5
±2.0
±10
±5
±1
mV
%FSO
Offset position sensitivity (±1 g)
Notes:
3
Full scale span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure.
4
Total accuracy includes non-linearity, hysteresis, repeatability, zero offset and span error, thermal effect on zero offset and span.
Non-linearity refers to the
Best Straight Line
fit measured for offset pressure, full-scale pressure and �½ full-scale pressure.
January 2008 / 564
3/6
www.sensortechnics.com