DCXL...DS Series
SURSENSE
TM
precision very low pressure sensors
/ mV-output
DCXL05DS
PERFORMANCE CHARACTERISTICS
Characteristics
Min.
-0.5
19
Span
Offset
±50
±10
10
1.5
6
kΩ
V
V
S
= 12 V, T
A
= 25 °C, common-mode pressure = 0 psig, pressure applied to port 2
Typ.
0
20
Max.
+0.5
21
±0.25
±200
±150
Unit
mV
%FSS
Zero pressure offset
Full scale span (FSS)
2
Combined non-linearity and hysteresis
3
Temperature effects (0 to 50°C)
4
Offset warm-up shift
5
Offset position sensitivity (±1 g)
Input resistance
Output resistance
Common mode voltage
6
µV
DCXL10DS
PERFORMANCE CHARACTERISTICS
Characteristics
Min.
-0.5
19
Span
Offset
±50
±10
13
1.5
6
kΩ
V
V
S
= 12 V, T
A
= 25 °C, common-mode pressure = 0 psig, pressure applied to port 2
Typ.
0
20
Max.
+0.5
21
±0.25
±200
±150
Unit
mV
%FSS
Zero pressure offset
Full scale span (FSS)
2
Combined non-linearity and hysteresis
3
Temperature effects (0 to 50°C)
4
Offset warm-up shift
5
Offset position sensitivity (±1 g)
Input resistance
Output resistance
Common mode voltage
6
µV
September 2006 / 633
3/5
www.sensortechnics.com