FBA Series
Mass flow sensors for gases
FEATURES
· Ranges 0...30 to 0...±1000 sccm
1
· 1...5 V or 1...3.75 V output
· Actual mass flow sensing
· Sensortechnics PRO services
MEDIA COMPATIBILITY
To be used with dry gases only
The FBA series is NOT designed for liquid
flow and will be damaged by liquid flow through
the sensor
SPECIFICATIONS
Maximum ratings
Supply voltage
2
8 to 15 V
typ. 10 ±0.01 V
ELECTRICAL CONNECTION
P1
P2
Power consumption
FBAL001DB
all others
Temperature limits
Operating
Storage
Mechanical shock
typ. 100 mW
typ. 50 mW, max. 60 mW
-25 to 85°C
-40 to 90°C
100 g (5 drops, 6 axes)
1 2 3
Note:
1
sccm denotes standard cubic centimeters per minute
2
Output voltage is ratiometric to supply voltage
Pin 1: V
out
Pin 2: +V
s
Pin 3: GND
E / 11722 / A