HCE Series
Miniature amplified pressure sensors
PHYSICAL DIMENSIONS AND ELECTRICAL CONNECTIONS (cont.)
HCE...Q8...
SMD dual port, opposite side
Straight ports
Bottom view
12.70
5 6 7 8
Pin
1
2
3
Connection
+Vs
GND
Vout
MISO
C LK
SS
I/C *
MOSI
2
9.50
16
1.28
4
5
6
7
8
4 3 2 1
10.70
4.20
3
HIGH PRESSURE PORT
3
6.70
LOW PRESSURE PORT
4.06
* Internal connection.
Do not connect for any reason
1.90
0.46
2.54
third angle projection
dimensions in mm
HCE...Q9...
SMD dual port, opposite side
Barbed ports
Top view
12.7
8 7 6 5
6.2
4.0
Pin
1
2
3
4
5
6
Connection
+Vs
GND
Vout
MISO
C LK
SS
I/C *
MOSI
16
10.5
1 2 3 4
10.7
3.1
6.9
7
8
LOW PRESSURE PORT
5.0
HIGH PRESSURE PORT
* Internal connection.
Do not connect for any reason
2.2
6.0
Ø 2.2
Ø 3.0
third angle projection
dimensions in mm
9/11
E / 11652 / A
www.sensortechnics.com