HCE Series  
Miniature amplified pressure sensors  
SPI - SERIAL PERIPHERAL INTERFACE  
Introduction  
In general the HCE series supports all combinations of  
clock phase (CPHA) and polarity (CPOL). By default it is  
programmed to CPHA = 0 and CPOL = 0, which means  
that data transmission starts with the rising first clock edge  
(see Fig 1).  
The HCE is capable to generate a digital output signal.  
The device runs a cyclic program, which will store a corrected  
sensor value with 14 bit resolution about every 500 µs within  
the output registers of the internalASIC. This cyclic program  
runs independent from the bus communication. In order to  
use the pressure sensor for digital signal readout, it should  
be connected to a SPI Master device.  
Slave select  
The falling edge of the SS line indicates the beginning of  
the transfer. Additionally the SS line must not be negated  
and reasserted between the three bytes to be transmitted.  
SPI specifies four signals: The clock (CLK) is generated by  
the master and input to all slaves. MOSI carries data from  
master to slave. MISO carries data from slave back to  
master. A slave select line (SS) allows individual selection  
of a slave device.  
Data operation  
The MOSI line should always be set to high level. So there  
is no data transmission from master to slave. Because of  
internal configuration the slave will answer the first byte  
with an FFxh. The second and third byte contain the 15 bit  
pressure information (see Fig. 2).  
SPI Modes  
A pair of parameters called clock polarity (CPOL) and clock  
phase (CPHA) determine the edges of the clock signal on  
which the data are driven and sampled. Each of the two  
parameters has two possible states, which allows for four  
possible combinations, all of which are incompatible with  
one another.  
For further information please refer to  
Sensortechnics SPI bus application note  
SCK cycle  
1
2
3
4
5
6
7
8
SCK  
(CPOL=0)  
MSB  
LSB  
LSB  
MOSI  
MISO  
MSB  
SS  
Sampling  
Fig. 1: Example of a standard 1 byte SPI data transfer for CPHA=0 and CPOL=0  
Data Byte 1  
Data Byte 2  
Data Byte 3  
MOSI  
MISO  
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
X
X
X
X
X
X
X
X
X P14 P13 P12 P11 P10 P9 P8 P7 P6 P5 P4 P3 P2 P1 P0  
Relevant data  
Fig. 2: 3 byte data stream between HCE sensor and master containing the pressure value as a 15 bit information  