欢迎访问ic37.com |
会员登录 免费注册
发布采购

HCLA02X5EU 参数 Datasheet PDF下载

HCLA02X5EU图片预览
型号: HCLA02X5EU
PDF下载: 下载PDF文件 查看货源
内容描述: 微型扩增低压传感器 [Miniature amplified low pressure sensors]
分类和应用: 传感器
文件页数/大小: 15 页 / 192 K
品牌: SENSORTECHNICS [ SENSORTECHNICS GMBH ]
 浏览型号HCLA02X5EU的Datasheet PDF文件第1页浏览型号HCLA02X5EU的Datasheet PDF文件第3页浏览型号HCLA02X5EU的Datasheet PDF文件第4页浏览型号HCLA02X5EU的Datasheet PDF文件第5页浏览型号HCLA02X5EU的Datasheet PDF文件第6页浏览型号HCLA02X5EU的Datasheet PDF文件第7页浏览型号HCLA02X5EU的Datasheet PDF文件第8页浏览型号HCLA02X5EU的Datasheet PDF文件第9页  
HCLA Series
Miniature amplified low pressure sensors
PRESSURE SENSOR CHARACTERISTICS
(V
s
= 5.0 V, T
A
= 25 °C, analog output signal is
ratiometric
to V
S
, digital output signal is
not ratiometric
to V
S
,
pressure applied to high pressure port)
Part no.
HCLA02X5...B
HCLA12X5...B
HCLA0025...B
HCLA0050...B
HCLA0075...B
HCLA02X5...U
HCLA12X5...U
HCLA0025...U
HCLA0050...U
HCLA0075...U
Operating pressure
0...±2.5 mbar
0...±12.5 mbar
0...±25 mbar
0...±50 mbar
0...±75 mbar
0...2.5 mbar
0...12.5 mbar
0...25 mbar
0...50 mbar
0...75 mbar
Proof pressure
5,7
250 mbar
250 mbar
500 mbar
750 mbar
1200 mbar
250 mbar
250 mbar
500 mbar
750 mbar
1200 mbar
Burst pressure
6,7
500 mbar
500 mbar
750 mbar
1200 mbar
2000 mbar
500 mbar
500 mbar
750 mbar
1200 mbar
2000 mbar
Output signal
2.25 ±2 V
0.25 - 4.25 V
Specification notes:
1.
Shift is relative to 25°C.
2.
Shift is within the first hour of excitation applied to the device.
3.
Non-linearity refers to the
Best Straight Line
fit, measured for lowest specified pressure, highest specified pressure and 1/2 full
scale pressure.
4.
Full Scale Span (FSS) is the algebraic difference between the output signal for the highest and lowest highest
pressure.
5.
Proof pressure is the maximum pressure which may be applied without causing durable shifts of the electrical parameters
of the sensing element.
6.
Burst pressure is the maximum pressure which may be applied without causing damage to the sensing element or leaks to
the housing.
7.
The common mode pressure for the HCLA series is 2 bar. Common mode pressure is the maximum pressure that can be
applied to both ports of a differential pressure sensor simultaneously without damaging the sensor housing.
8.
Max. delay time between pressure change at the pressure die and signal change at the output.
9.
The response time depends on the adjusted internal A/D resolution of the sensor. For 12 bit it is typ. 0.5 ms. Other A/D
resolutions and reponse times are available on request. Please contact Sensortechnics for further information.
10.
Sensors with lower current consumption are available on request. Please contact Sensortechnics for further information.
E / 11629 / A
2/15