欢迎访问ic37.com |
会员登录 免费注册
发布采购

XPC01GTC 参数 Datasheet PDF下载

XPC01GTC图片预览
型号: XPC01GTC
PDF下载: 下载PDF文件 查看货源
内容描述: 精密补偿压力传感器/ mV的输出 [Precision compensated pressure sensors / mV-output]
分类和应用: 传感器换能器压力传感器
文件页数/大小: 6 页 / 103 K
品牌: SENSORTECHNICS [ SENSORTECHNICS GMBH ]
 浏览型号XPC01GTC的Datasheet PDF文件第1页浏览型号XPC01GTC的Datasheet PDF文件第3页浏览型号XPC01GTC的Datasheet PDF文件第4页浏览型号XPC01GTC的Datasheet PDF文件第5页浏览型号XPC01GTC的Datasheet PDF文件第6页  
XPC/XPCL Series
C-grade
Precision compensated pressure sensors
/ mV-output
SPECIFICATIONS
Maximum ratings
(for all devices)
Supply voltage V
S
Lead temperature (soldering 5 seconds)
Common mode pressure
3 to 16 V
315°C
50 psig
Environmental specifications
(for all devices)
Temperature range
Compensated
Operating
Storage
Humidity limits (non-condensing)
0 to 70°C
-25 to 85°C
-40 to 125°C
0 to 95 %RH
PRESSURE SENSOR CHARACTERISTICS
V
S
= 12 V, T
A
= 25°C, pressure applied to port P1
7
Part no.
XPCL04...
XPCL10...
XPC0.3...
XPC01...
XPC05...
XPC15...
XPC30...
XPC60...
XPC100...
XPC150...
Operating
pressure
4 "H
2
O
10 "H
2
O
0.3 psi
1 p si
5 p si
1 5 p si
3 0 p si
6 0 p si
1 0 0 p si
1 5 0 p si
Proof
pressure
1
3 p si
3 p si
3 p si
3 p si
1 5 p si
4 5 p si
9 0 p si
1 8 0 p si
2 5 0 p si
2 5 0 p si
Burst
pressure
2
5 p si
5 p si
5 p si
5 p si
2 5 p si
7 5 p si
1 5 0 p si
3 0 0 p si
4 0 0 p si
4 0 0 p si
Full scale span
3
Min.
23 mV
19 mV
19 mV
17 mV
57 mV
85 mV
85 mV
85 mV
95 mV
85 mV
Typ.
25 mV
20 mV
20 mV
18 mV
60 mV
90 mV
90 mV
90 mV
100 mV
90 mV
Max.
27 mV
21 mV
21 mV
19 mV
63 mV
95 mV
95 mV
95 mV
105 mV
95 mV
PERFORMANCE CHARACTERISTICS
V
S
= 12 V, T
A
= 25°C, pressure applied to port P1
7
Characteristics
Zero pressure offset
Combined non-linearity and hysteresis
4
Temperature effects (0 to 70°C)
5
Input resistance
Output resistance
Response time (10 to 90 %FSS)
Common mode voltage
6
XPCL...
XPC...
Span
Offset
Min.
-1.0
Typ.
0
±0.25
Max.
+1.0
±1.0
±2.0
±1.0
Unit
mV
%FSS
mV
kΩ
µs
V
5
3
500
100
6
Notes
1
Proof pressure is the maximum pressure which may be applied without causing durable shifts of the electrical parameters of the sensing element.
2
Burst pressure is the maximum pressure which may be applied without causing damage to the sensing element or leaks from the housing.
3
Full scale span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure.
The span is ratiometric to the supply voltage.
4
Non-linearity refers to the
Best Straight Line
fit measured for offset pressure, full-scale pressure and �½ full-scale pressure.
5
Shift is relative to 25°C. The XPCL04... has a compensated temperature range from 0 to 50°C.
6
This is the common-mode voltage of the output arms (pins 2 and 4) for V
S
= 12 V.
7
For backside port devices (XPC...B...) pressure applied to P2.
2/6
June 2008 / 615